C3.3 Generator Set
- new - Products
- C3.3 Generator Set
At a glance data:
Maximum Rating:
65.0 kVA
Minimum Rating:
24.0 kVA
Emissions/Fuel Strategy:
EU Stage II R96/EUIIIa
Voltage:
110 to 480 Volts
Print
Electric Power Ratings Guide
24-220 KVA SA LVL 2 Enclosure
DE33E0, 50 Hz 33.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
DE33E3, 50 Hz 33.0 kVA, M Frame, Low EUIIIA Emissions Compliant Spec Sheet
DE40E0S, 50 Hz 40.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
DE50E2, 50 Hz 50.0 kVA, M Frame, EUII Emissions Compliant Spec Sheet
DE65E0, 50 Hz 55.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
DE55E0, 50 Hz 55.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
DE26E0S, 50 Hz 26.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
DE26E3S, 50 Hz 26.0 kVA, M Frame, EUIIIA Emissions Compliant Spec Sheet
DE40E2S, 50 Hz 40.0 kVA, M Frame, EUII Emissions Compliant Spec Sheet
DE50E0S, 50 Hz 50.0 kVA, M Frame, Low BSFC Emissions Compliant Spec Sheet
DE33E0, 50 Hz 33.0 kVA, 60 Hz 37.5 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE33E3, 50 Hz 33.0 kVA, LC Frame, EUIII Emissions Compliant Spec Sheet
DE50E0, 50 Hz 50.0 kVA, 60 Hz 56.3 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE50E2, 50 Hz 55.0 kVA, LC Frame, EU II Emissions Compliant Spec Sheet
DE65E0, 50 Hz 65.0 kVA, 60 Hz 75.0 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE55E0, 50 Hz 55.0 kVA, 60 Hz 62.5 LC Frame, Low BSFC Emissions Compliant Spec Sheet
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
65.0 kVA
Minimum Rating:
24.0 kVA
Emissions/Fuel Strategy:
EU Stage II R96/EUIIIa
Voltage:
110 to 480 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
Cat® C3.3
Bore:
4.1in
Stroke:
5in
Displacement:
201.4in³
Compression Ratio:
17.25:1, 19.25:1
Aspiration:
Turbocharged
Fuel System:
Direct Injection
Governor Type:
Mechanical
Generator Set Dimensions
Length - Maximum:
43.9in
Width - Maximum:
38.2in
Height - Maximum:
53.6in
Standard Equipment
air inlet system
- Air cleaner; light duty with disposable element
control panel
- GCCP 1.3
cooling system
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
exhaust system
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
fuel system
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
generators and generator attachments
- Voltage regulator (single phase sensing)
- Tower panel, IP22, bottom cable entry
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Segregated low voltage (AC/DC) wiring panel
governing system
- Mechanical and electrical governing system - model dependant
generators and attachments
- 12 Leads
lube system
- Lubricating oil
- Oil drain line with valve
mounting system
- Captive linear vibration isolators between base and engine-generator
- Termination points for coolant and lube oil drain lines
- Includes lifting provision and drag points
starting / charging system
- 12V Battery with rack & cables
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
alternator system
- R Frame auxilliary winding
- Anti-condensation heater
- LC Frame alternator with coastal protection
- LC Frame alternator
- Permanent magnet excitation (PMG)
circuit breakers
- Padlockable breaker device
- 4 Pole Circuit breaker to 250A
control panels
- GCCP 1.3
control panel options
- Emergency stop with key
cooling system
- Low coolant level shutdown
- Coolant heater
- Low coolant temperature alarm
certifications
- Global Certification for CIS
- European upgrade to STD set for "CE"
enclosures
- Sound attenuated level 1 enclosure (GALV)
- CEE for sockets for enclosure
- Sound attenuated level 2 enclosure CE
- Rental pack (CAE only)
- Socket blanking plate
fuel system
- High fuel level alarm
- Open set narrow tankbase
- Compact skidbase for open sets
- Low fuel level shutdown
- Low fuel level alarm
- Skidbase for CALG enclosure sets
- Bunded fuel tank
mounting options
- Battery removal
- Residential silencer
- Silencer installation kit
- External single point lift - enclosure
- Electronic governor
special packing inspections
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
general
- Packing case - compact set
- Packing case - canopied set
30-220 kVA SA Lvl 1 Enclosure
Maximum Rating:
65.0 kVA
Minimum Rating:
24.0 kVA
Emissions/Fuel Strategy:
EU Stage II R96/EUIIIa
Voltage:
110 to 480 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
65.0 kVA
Minimum Rating:
24.0 kVA
Emissions/Fuel Strategy:
EU Stage II R96/EUIIIa
Voltage:
110 to 480 Volts
C9 Generator Set
Maximum Rating:
65.0 kVA
Minimum Rating:
24.0 kVA
Emissions/Fuel Strategy:
EU Stage II R96/EUIIIa
Voltage:
110 to 480 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
65.0 kVA
Minimum Rating:
24.0 kVA
Emissions/Fuel Strategy:
EU Stage II R96/EUIIIa
Voltage:
110 to 480 Volts