C3.3 Generator Set
- new - Products
- C3.3 Generator Set
At a glance data:
Maximum Rating:
60.0 ekW
Minimum Rating:
27.0 ekW
Emissions/Fuel Strategy:
EU Stage II & R96/EUIIIa
Voltage:
110 to 480 Volts
Print
Electric Power Ratings Guide
DE33E0, 50 Hz 33.0 kVA, 60 Hz 37.5 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE33E3, 50 Hz 33.0 kVA, LC Frame, EUIII Emissions Compliant Spec Sheet
DE50E0, 50 Hz 50.0 kVA, 60 Hz 56.3 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE50E2, 50 Hz 55.0 kVA, LC Frame, EU II Emissions Compliant Spec Sheet
DE65E0, 50 Hz 65.0 kVA, 60 Hz 75.0 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE55E0, 50 Hz 55.0 kVA, 60 Hz 62.5 LC Frame, Low BSFC Emissions Compliant Spec Sheet
DE56E0, 60 Hz 49.2 kVA, Non-Certified Emissions Compliant Spec Sheet
DE75E0, 60 Hz 65.0 kVA, Non-Certified Emissions Compliant Spec Sheet
24-220 KVA SA LVL 2 Enclosure
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
60.0 ekW
Minimum Rating:
27.0 ekW
Emissions/Fuel Strategy:
EU Stage II & R96/EUIIIa
Voltage:
110 to 480 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
Cat® C3.3
Bore:
4.1in
Stroke:
5in
Displacement:
201.4in³
Compression Ratio:
17.25:1, 19.25:1
Aspiration:
Turbocharged
Fuel System:
Direct Injection
Governor Type:
Mechanical
Generator Set Dimensions
Length - Maximum:
43.9in
Width - Maximum:
38.2in
Height - Maximum:
53.6in
Standard Equipment
air inlet system
- Air cleaner; light duty with disposable element
control panel
- GCCP 1.3
cooling system
- Coolant drain line with valve
- Caterpillar extended life coolant
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
exhaust system
- Stub pipe, gaskets, raincap & SAE exhaust flange for customer use - shipped loose
fuel system
- Standard open set fuel tank/base supplied
- Base, formed steel with single wall integral 8-hour fuel tank
generators and generator attachments
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Tower panel, IP22, bottom cable entry
- 12 Leads
- Voltage regulator (single phase sensing)
- Segregated low voltage (AC/DC) wiring panel
governing system
- Mechanical governing system - model dependant
- Mechanical and electrical governing system - model dependant
lube system
- Lubricating oil
- Oil drain line with valve
mounting system
- includes lifting provisions and termination points for coolant
- Includes lifting provision and drag points
- Termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
starting / charging system
- 12V Battery with rack & cables
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
alternator system
- LC Frame alternator
- Anti-condensation heater
- Permanent magnet excitation (PMG)
- LC Frame alternator with coastal protection
- R Frame auxilliary winding
alternator
- Alternator removal options
circuit breakers
- 4 Pole Circuit breaker to 250A
- Padlockable breaker device
control panels
- GCCP 1.3
control panel options
- Overload shutdown via breaker
- Volt free contacts
- Earth leakage (2 wire only)
- Speed adjust potentiometer
- Voltage adjust potentiometer
- Battery charger
- Control panel heater
- Earth fault (2 wire only)
- Panel mounted audible alarm
- Emergency stop with key
cooling system
- Coolant heater
- Low coolant level shutdown
- Low coolant temperature alarm
certifications
- European upgrade to STD set for "CE"
- Global certification for CIS
enclosures
- CEE for sockets for enclosure
- Socket blanking plate
- Sound attenuated level 1 enclosure (GALV)
- Sound attenuated level 2 enclosure CE
- Rental pack (CAE only)
fuel system
- Skidbase for CALG enclosure sets
- Low fuel level shutdown
- High fuel level alarm
- Compact skidbase for open sets
- Low fuel level alarm
- Bunded fuel tank
- Open set narrow tankbase
mounting options
- Silencer installation kit
- Battery removal
- Electronic governor
- Residential silencer
- External single point lift - enclosure
special packing inspections
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
general
- Stone guards/rad trans flange
- Packing case - compact set
- Packing case - canopied set
30-220 kVA SA Lvl 1 Enclosure
Maximum Rating:
60.0 ekW
Minimum Rating:
27.0 ekW
Emissions/Fuel Strategy:
EU Stage II & R96/EUIIIa
Voltage:
110 to 480 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
60.0 ekW
Minimum Rating:
27.0 ekW
Emissions/Fuel Strategy:
EU Stage II & R96/EUIIIa
Voltage:
110 to 480 Volts
C9 Generator Set
Maximum Rating:
60.0 ekW
Minimum Rating:
27.0 ekW
Emissions/Fuel Strategy:
EU Stage II & R96/EUIIIa
Voltage:
110 to 480 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
60.0 ekW
Minimum Rating:
27.0 ekW
Emissions/Fuel Strategy:
EU Stage II & R96/EUIIIa
Voltage:
110 to 480 Volts