Skip to content

C13 (50 Hz) China Non Road

At a glance data:

Maximum Rating:
450 kVA
Minimum Rating:
350 kVA
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
380 to 415 Volts

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Maximum Rating:
450 kVA
Minimum Rating:
350 kVA
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
380 to 415 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby, Prime

Engine Specifications

Engine Model:
C13 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore:
5.12in
Stroke:
6.18in
Displacement:
762.8in³
Compression Ratio:
16.3:1
Aspiration:
Air to Air Aftercooled
Fuel System:
MEUI
Governor Type:
Adem™A4

Generator Set Dimensions

Length - Maximum:
186.7in
Width - Maximum:
79.3in
Height - Maximum:
84in

Standard Equipment

air inlet system

  • Air cleaner; light duty with disposable paper filter
  • Turbocharger
  • Aftercooler core

control panel

  • GCCP 1.3

cooling system

  • Radiator and cooling fan with guard
  • Coolant drain line with valve
  • Fan drive, battery charging alternator drive
  • Caterpillar extended life coolant

exhaust system

  • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange for customer use - shipped loose

fuel system

  • Primary fuel filter w/integral water separator and secondary filter
  • Flexible fuel lines
  • Fuel priming pump
  • Engine fuel transfer pump
  • Fuel coolers with single wall integral 8-hour fuel tank

generator and attachments

  • Integrated voltage regulator (IVR)
  • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
  • A Frame generator - IP21 Protection
  • Power center, IP22
  • Optional LC Frame generator - IP23 Protection
  • Segregated low voltage (AC/DC) wiring panel

governing system

  • Cat electronic governor (ADEM A4)

lube system

  • Lubricating oil
  • Oil drain valves

packaged generator set

  • Service indicator
  • Disposable air filter
  • Coolant level sight gauge
  • Low coolant level sensor
  • Coolant drain line with valve
  • Radiator package mounted

mounting system

  • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines.

starting / charging system

  • 24V battery with rack and cables

general

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

european certificates

  • Global Certification for CIS
  • EU Certificate of Conformance (CE)

air inlet system

  • Single element air cleaner
  • Dual element air cleaner

circuit breakers

  • Padlockable circuit breaker device
  • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
  • 3 Pole (IEC-100% rated) Circuit breaker
  • 4 Pole (IEC-100% rated) Circuit breaker
  • Circuit breaker (IEC) Auxiliary contacts
  • Shunt trip for IEC circuit breaker
  • 4 Pole (IEC-100% rated) Circuit breaker - Motorised

control panels

  • Local alarm modules: Local annunciator
  • Volt free contacts
  • GCCP 1.4
  • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
  • Remote annunciator module

cooling system

  • Radiator duct flange
  • Low coolant temperature alarm
  • Stone guards

enclosures

  • High ambient sound attenuated enclosures
  • Sound attenuated enclosures

exhaust system

  • 10, 25 and 35 dBA attenuation
  • Mufflers - End in/end out
  • 6 and 8 inch flange GP
  • Flexible 8 inch exhaust fittings
  • 6 and 8 inch elbow kit

fuel system

  • Fuel transfer system controls
  • Integral dual wall fuel tank base
  • Manual fuel transfer pump

generator and attachments

  • Space heaters
  • LC frame generator
  • LC frame oversize generator
  • LC CIP generator
  • A Frame oversize generator
  • A Frame CIP generator
  • Permanent magnet excitation (PMG) generator
  • Ingress protection

lube system

  • Manual sump pump

mounting system

  • Narrow skid base

starting / charging system

  • 5 Amp single Battery charger
  • Jacket water heater
  • Battery disconnect switch
Enclosure

C13 Sound Attenuated Enclosure 50 and 60 Hz

Maximum Rating:
450 kVA
Minimum Rating:
350 kVA
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
380 to 415 Volts