C4.4 Generator Set
- new - Products
- C4.4 Generator Set
At a glance data:
Maximum Rating:
60 ekW
Minimum Rating:
36 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
Print
Electric Power Ratings Guide
60 Hz 40 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 60 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 50 ekW, EPA Tier III Compliant Emissions Spec Sheet
60 Hz 36 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 40 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 45 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 50 ekW, SCAQMD & US EPA Tier 3 equivalent Compliant Emissions Spec Sheet
60 Hz 60 ekW, U.S. EPA Certified for Stationary Emergency Application Compliant Emissions Spec Sheet
60 Hz 55 ekW, U.S. EPA Certified for Stationary Emergency Application Compliant Emissions Spec Sheet
C4.4 Diesel Generator Set, 60 Hz, 40 - 60 ekW, Spec Sheet
GCCP 1.2 Control Panel Data Sheet
24-220 KVA SA LVL 2 Enclosure
GCCP 1.5 Control Panel Data Sheet
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
60 ekW
Minimum Rating:
36 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
C4.4, In-line 4, 4-cycle diesel
Bore:
4.13in
Stroke:
5in
Displacement:
268.5in
Compression Ratio:
18.2:1
Aspiration:
Turbocharged
Fuel System:
Electronic (adjustable)
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Maximum:
75.8in
Width - Maximum:
44.1in
Height - Maximum:
53.6in
Standard Equipment
certificates
- IBC seismic and wind Certifications
charging system
- NFPA battery charger UL10A 120VAC
air inlet system
- Air cleaner
- Cartridge type air filter
circuit breakers
- Second circuit breaker box
- 3-Pole 100% rated
- Power terminal strip
- Breakers (100% UL rated)
control panel
- 1000028996
exhaust system
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
fuel system
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
cooling system
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Radiator stone guard
generator
- 12 Leads
governing system
- Mechanical and electrical governing system - model dependent
lube system
- Oil drain line with valve
- Lubricating oil
control panels
- WCA1 Low coolant temperature alarm
- WSS1 Low coolant level shut down
- FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
- NFPA110 bundle includes:
- PAA1 Panel mounted audible alarm
- A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
- Oil temperature gauge and sender
- PBC10NU NFPA battery charger
- Ground fault relay
- Discrete I/O module
- Volt free contacts genset run and common alarm
- Audible alarm
- Remote E-stop button
- Remote annunciator module
- Low coolant temperature alarm
- Protective devices:
- Overload shutdown via breaker
- Fuel level reading
- Low coolant level shutdown
general
- Engine and alternator pre-paint, Caterpillar yellow
starting/charging system
- 24V battery with rack and cables
- Batteries
Optional Equipment
certificates
- IBC seismic and wind Certifications
alternator system
- R Frame auxilliary winding
air inlet system
- Cartridge type air filter
charging system
- NFPA battery charger UL10A 120VAC
circuit breakers
- 3-Pole 100% rated
- Breakers (100% UL rated)
- Second circuit breaker box
- Power terminal strip
control panels
- Discrete I/O module
- Remote annunciator module
- Remote E-stop button
- Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
- Ground fault relay
- Audible alarm
- Oil temperature gauge and sender
- Volt free contacts genset run and common alarm
- NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
heating elements
- Coolant heater
- Battery heater
- Anti-condensation heater
- Lube oil sump heater
- Jacket water heater
- Wiring for canopy space heater
cooling system
- Radiator transition flange
enclosures
- Panel viewing window
- External emergency stop
- Sound attenuated enclosure, Level 2
- Weatherproof enclosure
- Sound attenuated enclosure, Level 1
fuel system
- 5 Gallon fill containment
- Tank riser
- 209 and 394 gallon sub-base fuel tanks
- Emergency vent pipe
- 5 Gallon spill containment
mounting system
- Seismic vibration isolators
tests
- Generator test report
- PGS Test report @ 0.8 power factor
- 4 Hour factory test
- PGS Test report @ 1.0 power factor
exhaust system
- 10, 25 and 35 dBA silencer systems
- Overhead silencer mounting kit
generators
- Permanent magnet excitation (PMG) generator
30-220 kVA SA Lvl 1 Enclosure
Maximum Rating:
60 ekW
Minimum Rating:
36 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
60 ekW
Minimum Rating:
36 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
C9 Generator Set
Maximum Rating:
60 ekW
Minimum Rating:
36 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
60 ekW
Minimum Rating:
36 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts