C18 Generator Set
- new - Products
- C18 Generator Set
At a glance data:
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
Print
Electric Power Ratings Guide
C18, DE650SE0, 60 Hz, 650 ekW Standby, 600 ekW Prime, Low BSFC Spec Sheet
C18, DE715SE0, 60 Hz, 716 ekW Standby, 650 ekW Prime, Low BSFC Spec Sheet
C18, DE750SE0, 60 Hz, 750 ekW Standby, 680 ekW Prime, Low BSFC Spec Sheet
C18, DE550SE0, 60 Hz, 550 ekW Standby, 500 ekW Prime, Non-Certified Emissions Spec Sheet
C18 for industrial applications
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore:
5.71in
Stroke:
7.2in
Displacement:
1106.4in³
Compression Ratio:
14.5:1
Aspiration:
Air to Air Aftercooled
Fuel System:
Electronic unit injection
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Maximum:
218.5in
Width - Maximum:
80.9in
Height - Maximum:
107.8in
Standard Equipment
air inlet
- Air cleaner
air inlet system
- Light duty air cleaner
- Turbocharger
- Aftercooler core
governing system
- Cat electronic governor (ADEM A4)
control system
- GCCP 1.2
cooling
- Radiator and cooling fan with guard
- Fan drive, battery charging alternator drive
- Coolant drain line with valve
- Caterpillar extended life coolant
- Package mounted radiator
exhaust
- Exhaust flange outlet
exhaust system
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
fuel
- Fuel priming pump
- Secondary fuel filters
- Primary fuel filter with integral water separator
fuel system
- Standard 8 hour open set fuel tank
generator and attachments
- Matched to the performance and output characteristics of Cat engines
- Integrated voltage regulator (IVR)
- Segregated low voltage (AC/DC) wiring panel
- A Frame generator - IP21 protection
- Integrated voltage regulator (IVR)
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Power center, IP22
generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
power termination
- Busbar
control panel
- GCCP Genset Controller
lube system
- Lubricating oil
- Oil drain valves
mounting
- Rubber vibration isolators
mounting system
- Captive linear vibration isolators between base and engine-generator. includes lifting provisions and termination points for coolant and lube oil drain lines
starting/charging
- 24 Volt battery with rack and cables
- 24 volt starting motor
- Batteries
general
- Engine and alternator pre-paint, Caterpillar yellow
- Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment
air inlet system
- Dual element air cleaner
- Single element air cleaner
exhaust
- Industrial, residential, critical mufflers
circuit breakers
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
- Power terminal strip
- 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
- Shunt trip for IEC breaker
- Padlockable circuit breaker device
- Circuit breaker (IEC) Auxiliary contacts
- 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
- 4 Pole (IEC-100% rated) Circuit breakers - Motorised
generator
- Anti-condensation heater
- Oversize and premium generators
- Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
power termination
- Circuit breakers, UL listed
- Circuit breakers, IEC compliant
control panels
- Load share module
- Local & remote annunciator modules
- GCCP 1.2, GCCP 1.5
- Remote monitoring software
- Digital I/O module
control system
- Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
- Local alarm modules
- Local alarm horn
- Oil temperature displays
- GCCP 1.5
- Volt free contact
- Remote annunciator module
starting/charging
- Heavy duty starting system
- Battery chargers
- Jacket water heater
- Charging alternator
- Oversize batteries
cooling system
- Low coolant temperature alarm
- Radiator duct flange
enclosures
- Sound attenuated enclosures
exhaust system
- Engine mounted muffler
- 8 and 10 inch GP flanges
- 10, 25 and 35 end in / end out mufflers
- Manifold and turbocharger guards
- 8 and 10 inch elbow kits
fuel system
- Manual fuel transfer pump
- Integral - Dual wall fuel tank base
- Fuel transfer system
general
- CSA Certification
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- Integral & sub-base UL listed dual wall fuel tanks
- Narrow, wide or skid base
- Single or dual wall integral fuel tanks
- Automatic transfer switches (ATS)
- UL 2200 package
- The following options are based on regional and product configuration:
- Single or dual wall sub-base fuel tanks
- EEC Declaration of Conformity
- Sound attenuated, weather protective or high ambient weather protective enclosure
- Enclosures: Sound attenuated, weather protective
- EU Certificate of Conformance (CE)
generator and attachments
- Ingress protection
- Permanent magnet excitation (PMG)
- A Frame CIP generator
- LC frame generator
- LC frame oversize generators
- A Frame oversize generator
- LC frame CIP generator
- Space heaters
lube system
- Manual sump pump
starting and charging
- Jacket water heaters
- 5 Amp Battery charger
- Battery disconnect switch
C18 Sound Attenuated Enclosure 50 and 60 Hz
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
C13, C15, C18 SA enclosure. 350-600 kW 60 Hz
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
C13, C15, C18 WP Enclosure. 350-600 kW 60 Hz
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
C9 Generator Set
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
208 to 600 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
600 ekW
Minimum Rating:
455 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage: