Skip to content

Gas Generator G3512H

At a glance data:

Continuous Rating:
1515 ekW / 1505 ekW @1.0pf
Fuel Type:
Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency:
44.90%
Frequency:
50 / 60 Hz

Overview

G3512H Generator Set

Generator Set Specifications

Continuous Rating:
1515 ekW / 1505 ekW @1.0pf
Fuel Type:
Natural Gas, Hydrogen Blend (up to 25%)
Maximum Electrical Efficiency:
44.90%
Frequency:
50 / 60 Hz
RPM:
1500 rpm

Engine Specifications

Engine Model:
G3512H
Displacement:
3574in³
Aspiration:
TA
Bore:
6.7in
Stroke:
8.5in

Generator Set Dimensions

Length:
223in
Width:
76in
Height:
91in
Dry Weight - Genset:
31085lb

Engine Specifications

Governor Type:
ADEM A4

Standard Equipment

air inlet

  • Package Mounted Air Cleaner with service indicator

cooling

  • Jacket water and SCAC thermostats
  • 2nd Stage CAT Flange
  • ANSI Class 150 JW Connection
  • Engine driven pumps for jacket water and aftercooler cooling

control panels

  • Dedicated customer wiring terminals

control panel

  • EMCP4.3

exhaust

  • Dry exhaust manifolds insulated and shielded
  • Center section cooled turbocharger with Cat flanged outlet

generator

  • High efficiency low voltage Cat generator, permanent magnet excitation, digital regulation, IP23 water ingress protection, & form wound construction.

starting/charging

  • Electric Starter

general

  • Paint - Caterpillar Yellow except rails and radiators gloss black
  • Crankshaft vibration damper and guard

Optional Equipment

air inlet

  • Mounting brackets and piping
  • Air cleaner with precleaner

control panels

  • Remote annunciator

circuit breakers

  • Frame mounting circuit breaker orientation
  • 2500A 3-pole IEC rated circuit breakers
  • Rear Mounted Circuit Breaker
  • 3000A/3200A/4000A UL100% Rated Masterpact circuit breaker (60 Hz only)
  • LSI Long-Time, LSI-P Long-Time, LSIG Long-Time, LSIG-P Long-Time,

control panel

  • Language Options
  • Cable Shroud Location
  • Engine failure relay
  • Discrete I/O module, 12 digital points, 8 'Form C' relay
  • 16 point/32 light annunciator with NFPA99-110/CSA282 configuration
  • Empty Upper Box Right/Left
  • Local Alarm module
  • Synchronization module
  • Cat Connect: Ethernet, satellite, or cell telematics
  • Local/Remote PC Monitorring
  • Right/Left/Rear Extension Box

cooling

  • Remote radiator for JW and SCAC circuits
  • 220V (50Hz), 240V (60Hz), 480V (60Hz) JW heater

exhaust

  • Flexible fitting [305mm x 305mm (12in. X 12in.)] w/ 12 bolt-flanges
  • 406mm (16in.) sparking-arresting muffler with companion flange
  • Exhaust expander [250mm-329mm (10in-12in)]
  • 305mm (12 in.) flange
  • Muffler options
  • Elbow exhaust

fuel system

  • 1/2" NPT gas train conduit connectors
  • 3, 0-100kPag 4-20mA gas train pressure sensors
  • Fuel Filter
  • Gas knockdown regulators

general

  • Digital Diagnostic tool
  • US Aid emblem

generator

  • Generator air filter
  • Manual voltage control
  • Cable access box
  • RTD Monitorring
  • Bearing temperature detectors

governing system

  • ADEM A4 4-20mA (0-5V) speed input

starting/charging

  • Battery with cables and rack
  • 24V Starting motors
  • 20A, 24VDC battery charger
  • 45A, 24V charging alternator (requires engine driven pumps)
  • Jacket water heater

grid code compliance

  • 60 Hz: USA
  • 50 Hz: Germany, Great Britain, Belgium, Romania, Italy, Ireland, Poland, Netherlands, Spain, France, and European Standard