D400 GC (60 Hz) Generator Set
- new - Products
- D400 GC (60 Hz) Generator Set
At a glance data:
Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
Cat® C13 In-line 6, 4-cycle diesel
Bore:
5.1in
Stroke:
6.2in
Displacement:
763in³
Compression Ratio:
16.3:1
Aspiration:
Turbocharged Air-to-Air Aftercooled
Fuel System:
MEUI
Governor Type:
ADEM™A4
Generator Set Dimensions
Length - Maximum:
182.8in
Width - Maximum:
64.2in
Height - Minimum:
80.3in
Height - Maximum:
96.7in
Dry Weight - Genset (minimum):
7330.4lb
Dry Weight - Genset (maximum):
4107lb
Standard Equipment
air inlet system
- Air cleaner - Non canister, disposable
- Aftercooler core
- Turbocharger
control panel
- GCCP 1.2
cooling system
- Blower fan and fan drive with guards
- Coolant drain valve
- Radiator sight gauge
- Radiator, package mounted
- Jacket water pump, gear driven, centrifugal
- Thermostats and housing
exhaust system
- Exhaust manifold - dry
fuel system
- Primary fuel filter w/integral water separator and secondary filter, spin on
- Engine fuel transfer pump
- Fuel cooler
- Fuel priming pump
- Integral tank base, 24 hours, UL142
generator set
- All protective devices and control functions simulated and checked
- Complete system designed & built at ISO 9001:2000 certified facilities
- Factory tested to design specifications at full load conditions
generators and generator attachments
- Insulation system, Class H
- IP23 Protection
- Standard winding protection for non-harsh environments with relative humidity ? 95%
- 6 Leads
- Terminal box, IP22 RHS facing, bottom cable entry
- Easy access to AVR and terminals
- Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
- Voltage regulator (single phase sensing)
governing system
- Cat electronic governor (ADEM A4)
lube system
- Fumes disposal to front of radiator
- Lubricating oil, CK-4 (10W-30)
- Oil cooler
- Shallow oil pan
- Oil filler and dipstick
- Oil filter, spin on
- Oil drain with valve
mounting system
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provisions and termination points for coolant and lube oil drain lines
protection
- Safety shutoff - Low oil pressure
- Safety shutoff - High water temperature
- Safety shutoff - Overspeed
starting/charging system
- 24-volt electric starting motor
- 24V, 45 Amp Charging alternator
general
- Lifting eyes
- Vibration damper
- Parts book
Optional Equipment
air inlet system
- Air cleaner (Non canister disposable)
bases, mounting & fuel tanks
- Audio & visual fuel alarm (@90% fuel level)
- Integral tank base, 24 hours, UL142
- 5 Gallon Spill Containment
- Fuel tank pill pipe & lockable cap
- Overfill prevention valve
- Wide Base - Skid
circuit breaker
- 1200A LSI
- 1200A LS/I
- 600A LS/I
- 400A LS/I
- 800A LS/I
- 600A LSI
- Auxiliary contacts
- 800A LSI
- 400A LSI
control system
- Twist release, Red button emergency stop
- Ground fault relay
- Volt free contacts
- Audible alarm Gp
- 16 -light NFPA 99/110 Annunciator
- 20A GFCI (Ground Fault Circuit Interrupter)
- 100A Load center
- Product link remote monitoring hardware
enclosures
- AC & DC Source lights
- E-Stop
- Sound attenuated Level 2 enclosure (White)
exhaust system
- 8" Muffler - 25 dBA attenuation
- Manifold and turbocharger guards
- Flexible exhaust connection
generator
- Space heater
- Permanent magnet excitation (PMG) generator
circuit breakers
- 4 Pole (IEC-100% rated) Circuit breaker - Motorised
- Circuit breaker (IEC) Auxiliary contacts
- Shunt trip for IEC circuit breaker
starting system
- Oversize battery set, 1400 CCA, 200 amp/hr
- Standard battery set: 1000 CCA, 90 amp/hr.
- Jacket water heater
- Battery charger (UL Certified)
general
- Generator test report
- Extended Service Coverage
- UL2200 Certification
- CSA Certification
starting / charging system
- Jacket water heater
- Battery disconnect switch
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts
C9 Generator Set
Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts