Skip to content

D400 GC (60 Hz) Generator Set

At a glance data:

Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
EPA Stationary Emergency
Voltage:
480 to 600 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby

Engine Specifications

Engine Model:
Cat® C13 In-line 6, 4-cycle diesel
Bore:
5.1in
Stroke:
6.2in
Displacement:
763in³
Compression Ratio:
16.3:1
Aspiration:
Turbocharged Air-to-Air Aftercooled
Fuel System:
MEUI
Governor Type:
ADEM™A4

Generator Set Dimensions

Length - Maximum:
182.8in
Width - Maximum:
64.2in
Height - Minimum:
80.3in
Height - Maximum:
96.7in
Dry Weight - Genset (minimum):
7330.4lb
Dry Weight - Genset (maximum):
4107lb

Standard Equipment

air inlet system

  • Air cleaner - Non canister, disposable
  • Aftercooler core
  • Turbocharger

control panel

  • GCCP 1.2

cooling system

  • Blower fan and fan drive with guards
  • Coolant drain valve
  • Radiator sight gauge
  • Radiator, package mounted
  • Jacket water pump, gear driven, centrifugal
  • Thermostats and housing

exhaust system

  • Exhaust manifold - dry

fuel system

  • Primary fuel filter w/integral water separator and secondary filter, spin on
  • Engine fuel transfer pump
  • Fuel cooler
  • Fuel priming pump
  • Integral tank base, 24 hours, UL142

generator set

  • All protective devices and control functions simulated and checked
  • Complete system designed & built at ISO 9001:2000 certified facilities
  • Factory tested to design specifications at full load conditions

generators and generator attachments

  • Insulation system, Class H
  • IP23 Protection
  • Standard winding protection for non-harsh environments with relative humidity ? 95%
  • 6 Leads
  • Terminal box, IP22 RHS facing, bottom cable entry
  • Easy access to AVR and terminals
  • Brushless, self-excited 2/3 pitch (600V uses Internal excitation (IE))
  • Voltage regulator (single phase sensing)

governing system

  • Cat electronic governor (ADEM A4)

lube system

  • Fumes disposal to front of radiator
  • Lubricating oil, CK-4 (10W-30)
  • Oil cooler
  • Shallow oil pan
  • Oil filler and dipstick
  • Oil filter, spin on
  • Oil drain with valve

mounting system

  • Captive linear vibration isolators between base and engine-generator
  • Includes lifting provisions and termination points for coolant and lube oil drain lines

protection

  • Safety shutoff - Low oil pressure
  • Safety shutoff - High water temperature
  • Safety shutoff - Overspeed

starting/charging system

  • 24-volt electric starting motor
  • 24V, 45 Amp Charging alternator

general

  • Lifting eyes
  • Vibration damper
  • Parts book

Optional Equipment

air inlet system

  • Air cleaner (Non canister disposable)

bases, mounting & fuel tanks

  • Audio & visual fuel alarm (@90% fuel level)
  • Integral tank base, 24 hours, UL142
  • 5 Gallon Spill Containment
  • Fuel tank pill pipe & lockable cap
  • Overfill prevention valve
  • Wide Base - Skid

circuit breaker

  • 1200A LSI
  • 1200A LS/I
  • 600A LS/I
  • 400A LS/I
  • 800A LS/I
  • 600A LSI
  • Auxiliary contacts
  • 800A LSI
  • 400A LSI

control system

  • Twist release, Red button emergency stop
  • Ground fault relay
  • Volt free contacts
  • Audible alarm Gp
  • 16 -light NFPA 99/110 Annunciator
  • 20A GFCI (Ground Fault Circuit Interrupter)
  • 100A Load center
  • Product link remote monitoring hardware

enclosures

  • AC & DC Source lights
  • E-Stop
  • Sound attenuated Level 2 enclosure (White)

exhaust system

  • 8" Muffler - 25 dBA attenuation
  • Manifold and turbocharger guards
  • Flexible exhaust connection

generator

  • Space heater
  • Permanent magnet excitation (PMG) generator

circuit breakers

  • 4 Pole (IEC-100% rated) Circuit breaker - Motorised
  • Circuit breaker (IEC) Auxiliary contacts
  • Shunt trip for IEC circuit breaker

starting system

  • Oversize battery set, 1400 CCA, 200 amp/hr
  • Standard battery set: 1000 CCA, 90 amp/hr.
  • Jacket water heater
  • Battery charger (UL Certified)

general

  • Generator test report
  • Extended Service Coverage
  • UL2200 Certification
  • CSA Certification

starting / charging system

  • Jacket water heater
  • Battery disconnect switch