At a glance data:
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
C4.4, In-line 4, 4-cycle diesel
Bore:
4.1in
Stroke:
5in
Displacement:
269in³
Compression Ratio:
16.7:1
Aspiration:
Turbocharged
Fuel System:
Common Rail
Governor Type:
Mechanical, ADEM™A4
Generator Set Dimensions
Length - Maximum:
82.6in
Width - Maximum:
43.3in
Height - Maximum:
52.9in
Dry Weight - Genset (maximum):
2222lb
Standard Equipment
air inlet system
- Air cleaner; light duty with disposable element
- Air cleaner
cooling system
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Caterpillar extended life coolant
- Fan drive, battery charging alternator drive
control panel
- GCCP 1.2 Control panel
exhaust system
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
fuel system
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 24-hour fuel tank
generator
- Circuit breaker, IEC, 3 pole, mounted in tower panel
- IP23 Protection
- Tower panel, IP22, bottom cable entry
- 12 Leads
- Voltage regulator (single phase sensing)
- Segregated low voltage (AC/DC) wiring panel
governing system
- Mechanical and electrical governing system - model dependent
lube system
- Lubricating oil
- Oil drain line with valve
mounting system
- Termination points for coolant and lube oil drain lines
- Captive linear vibration isolators between base and engine-generator
- Includes lifting provision and drag points
starting/charging system
- Batteries
- 24V battery with rack and cables
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
alternator system
- Anti-condensation heater
- 3 phase sensing
- Permanent magnet excitation (PMG)
- R Frame auxilliary winding
- Quadrature droop kit
circuit breakers
- Circuit breaker upgrades - 4 Pole circuit reaker to 250A, 400A and 630 A
cooling system
- Coolant heater
- Low coolant temperature alarm
- Low coolant level shutdown
control panel options
- Earth fault (2 wire only)
- Control panel heater
- GCCP 1.2 Control panel
- Volt free contacts
- Emergency stop with key
- Voltage adjust potentiometer
- Overload shutdown via breaker
- Panel mounted audible alarm
- Battery charger
- Earth leakage (2 wire only)
- Speed adjust potentiometer
enclosures
- Sound attenuated Level 2 enclosure
fuel system
- Low fuel level alarm
- Bunded fuel tank
- Low fuel level shutdown
- High fuel level alarm
mounting options
- Battery removal
- Electronic governor
- Industrial silencer
- External single point lift - enclosure
- Silencer installation kit
special packing/inspectons for shipment
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
general - accessories / miscellaneous
- Packing case - canopied set
- Packing case - compact set
- Stone guards/rad trans flange
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
C9 Generator Set
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage:
208 to 600 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
U.S. EPA Cert., Tier 3
Voltage: