DE110 GC Generator Set (60 Hz)
- new - Products
- DE110 GC Generator Set (60 Hz)
At a glance data:
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
C4.4, In-line 4, 4-cycle diesel
Bore:
4.1in
Stroke:
5in
Displacement:
268.5in
Compression Ratio:
18.23:1
Aspiration:
Turbocharged Air To Air Charge Cooled
Fuel System:
Inline
Governor Type:
Mechanical
Generator Set Dimensions
Length - Maximum:
108.1in
Width - Maximum:
39.3in
Height - Maximum:
58.1in
Dry Weight - Genset (maximum):
2932lb
Standard Equipment
engine
- C4.4, Inline 4 cylinder, 4 stroke diesel
alternator
- A Frame standard alternator
fuel storage
- Single wall 8 hour fuel tank
genset control
- GCCP 1.1
governor
- Mechanical governor
enclosure
- Cat GC enclosure
air, cooling & exhaust
- Enclosure silencer
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance 13
auxiliary supply voltage
- 120V
alternator requirements
- Space heater
fuel storage
- Dual wall 8 hour fuel tank
- Low fuel level shutdown
- Single wall tank with containment
- Low fuel level alarm
- High fuel level alarm
genset control
- Volt free contacts for genset running
- Emergency stop with key
- Battery charger
- Earth fault
- USB to RS485 Communications device
- Panel mounted audible alarm
- Earth leakage
- Volt free contacts for common alarm
- USB to RS485 Communications device
- Coolant heater
- Battery
- Low coolant level shutdown
- Standby Pack (Smart Jacket water heater, Battery charger)
circuit breaker
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 3 Pole Circuit breaker 250A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 400A
- 4 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 250A
- Circuit breaker padlock
- 4 Pole Circuit breaker 400A
- Neutral earth link
- Overload via alarm switch on breaker
testing & packaging
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts
C9 Generator Set
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
100 ekW
Minimum Rating:
100 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts