DE55 GC Generator Set (60 Hz)
- new - Products
- DE55 GC Generator Set (60 Hz)
At a glance data:
Frequency:
60 Hz
Maximum Rating:
50 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Frequency:
60 Hz
Maximum Rating:
50 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage:
220 to 480 Volts
Minimum Rating:
50 ekW
Speed:
1800 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
Cat® C3.3, In-line 3, 4-cycle diesel
Bore:
4.1in
Stroke:
5in
Displacement:
201.4in³
Compression Ratio:
17.25:1
Aspiration:
Turbocharged
Fuel System:
Inline
Governor Type:
Mechanical
Generator Set Dimensions
Length - Maximum:
76.6in
Width - Maximum:
34.3in
Height - Maximum:
48.7in
Dry Weight - Genset (maximum):
2114lb
Standard Equipment
engine
- C3.3, Inline 3 cylinder, 4 stroke diesel
genset control
- GCCP 1.1
governor
- Mechanical governor
alternator
- A Frame standard alternator
fuel storage
- Single wall 8 hour fuel tank
enclosure
- Cat GC enclosure
air, cooling & exhaust
- Enclosure silencer
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance
alternator requirements
- Space heater
auxiliary supply voltage
- 120V
fuel storage
- Dual wall 8 hour fuel tank
- Low fuel level shutdown
- Single wall tank with containment
- Low fuel level alarm
- High fuel level alarm
genset control
- Battery charger
- Volt free contacts for genset running
- Volt free contacts for common alarm
- Emergency stop with key
- Earth leakage
- USB to RS485 Communications device
- Earth fault
- Panel mounted audible alarm
- Battery
- Standby Pack (Smart Jacket water heater, Battery charger)
- Coolant heater
- Low coolant level shutdown
circuit breaker
- 3 Pole Circuit breaker 63A
- 3 Pole Circuit breaker 80A
- 3 Pole Circuit breaker 100A
- 3 Pole Circuit breaker 125A
- 3 Pole Circuit breaker 160A
- 3 Pole Circuit breaker 200A
- 4 Pole Circuit breaker 63A
- 4 Pole Circuit breaker 80A
- 4 Pole Circuit breaker 100A
- 4 Pole Circuit breaker 125A
- 4 Pole Circuit breaker 160A
- 4 Pole Circuit breaker 200A
- Circuit breaker padlock
- Neutral earth link
- Overload via alarm switch on breaker
testing & packaging
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8PF
Similar Products
DE75AE0 (50 Hz) Generator Set
Frequency:
60 Hz
Maximum Rating:
50 ekW
Emissions/Fuel Strategy:
Non Regulated
Voltage: