DE400 GC Generator Set
- new - Products
- DE400 GC Generator Set
At a glance data:
Maximum Rating:
400 kVA
Minimum Rating:
400 kVA
Emissions/Fuel Strategy:
Non-Certified Emissions
Voltage:
380 to 415 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
400 kVA
Minimum Rating:
400 kVA
Emissions/Fuel Strategy:
Non-Certified Emissions
Voltage:
380 to 415 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
C9.3B, I-6, 4-cycle diesel
Bore:
4.53in
Stroke:
5.87in
Displacement:
567.5in³
Compression Ratio:
16.5:1
Aspiration:
Turbocharged Air-to-Air Aftercooled
Fuel System:
Common Rail
Governor Type:
ADEM™A6
Generator Set Dimensions
Length - Maximum:
104.8in
Width - Maximum:
44in
Height - Maximum:
69.5in
Dry Weight - Genset (maximum):
5070.6lb
Standard Equipment
engine
- C9.3B, Inline 6 cylinder, 4 stroke diesel
air, cooling & exhaust
- Standard air filter
genset control
- GCCP 1.1
governor
- Adem A4
alternator
- A Frame standard alternator
fuel storage
- Single wall 8 hour fuel tank
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
air, cooling & exhaust
- 6" Elbow kit
- Dual element air filter
- 5-6" Exhaust adapter
- Canopy silencer
- 5" Elbow kit
- 6" Elbow kit
- 6" Muffler - 25 dBA attenuation
- 5" Muffler - 10 dBA Attenuation
- Single stage air filter
- No muffler
alternator requirements
- IP Standard @ 21 FUW A-Frame
- Space heater
auxiliary supply voltage
- 240V
certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance 13
circuit breaker
- 3 Pole Circuit breaker 800A
- Circuit breaker padlock
- 4 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 1250A
- 3 Pole Circuit breaker 630A
- 4 Pole Circuit breaker 800A
- Overload via alarm switch on breaker
- Neutral earth link
- 3 Pole Circuit breaker 1250A
- Auxiliary contacts
- Shunt Trip
enclosure
- Cat GC enclosure
fuel storage
- Low fuel level shutdown
- Fuel level alarms
- Low fuel level alarm
- Single wall tank with containment 01
- High fuel level alarm
- Dual wall 8 hour fuel tank
genset control
- PLG Cellular 4G E
- Oil temperature displays
- Coolant heater
- Battery charger
- Standby Pack (Smart Jacket water heater, Battery charger)
- PLG Cellular 4G U
- Voltage adjust potentiometer
- Low coolant temperature alarm
- Speed adjust potentiometer
- PLG Ethernet
- Battery
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
400 kVA
Minimum Rating:
400 kVA
Emissions/Fuel Strategy:
Non-Certified Emissions
Voltage:
380 to 415 Volts
C9 Generator Set
Maximum Rating:
400 kVA
Minimum Rating:
400 kVA
Emissions/Fuel Strategy:
Non-Certified Emissions
Voltage:
380 to 415 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
400 kVA
Minimum Rating:
400 kVA
Emissions/Fuel Strategy:
Non-Certified Emissions
Voltage:
380 to 415 Volts