Skip to content

DE400S GC Generator Set

At a glance data:

Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Maximum Rating:
400 ekW
Minimum Rating:
400 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby

Engine Specifications

Engine Model:
C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore:
4.53in
Stroke:
5.87in
Displacement:
567.5in³
Compression Ratio:
16.5:1
Aspiration:
Air to Air Aftercooled
Fuel System:
Direct Injection
Governor Type:
Adem™A4

Generator Set Dimensions

Length - Maximum:
186.7in
Width - Maximum:
79.3in
Height - Maximum:
84in

Standard Equipment

engine

  • C9.3B, Inline 6 cylinder, 4 stroke diesel

genset control

  • GCCP 1.1

governor

  • Adem A4

alternator

  • A Frame standard alternator

fuel storage

  • Single wall 8 hour fuel tank

air, cooling & exhaust

  • Standard air filter

general

  • Engine and alternator pre-paint, Caterpillar yellow

Optional Equipment

european certificates

  • Australia, CIS, Gulf Certification
  • EU Certificate of Conformance (CE)

auxiliary supply voltage

  • 240V

alternator requirements

  • Space heater
  • IP Standard @ 21 FUW A-Frame

fuel storage

  • High fuel level alarm
  • Dual wall 8 hour fuel tank
  • Single wall tank with containment 01
  • Fuel level sender
  • Low fuel level shutdown
  • Low fuel level alarm

enclosure

  • Cat GC enclosure

genset control

  • Speed adjust potentiometer
  • Battery charger
  • Standby Pack (Smart Jacket water heater, Battery charger)
  • Voltage adjust potentiometer
  • PLG Cellular 4G E
  • Low coolant temperature alarm
  • Battery
  • Oil temperature displays
  • PLG Cellular 4G U
  • Coolant heater
  • PLG Ethernet

circuit breaker

  • Overload via alarm switch on breaker
  • 3 Pole Circuit breaker 1250A
  • Neutral earth link
  • 4 Pole Circuit breaker 630A
  • 4 Pole Circuit breaker 1250A
  • 4 Pole Circuit breaker 800A
  • Circuit breaker padlock
  • Auxiliary contacts
  • 3 Pole Circuit breaker 800A
  • Shunt Trip
  • 3 Pole Circuit breaker 630A

air, cooling & exhaust

  • 6" Elbow kit
  • 6" Elbow kit
  • 5" Elbow kit
  • 5-6" Exhaust adapter
  • Canopy silencer
  • 6" Muffler - 25 dBA attenuation
  • Dual element air filter
  • Single stage air filter
  • No muffler
  • 5" Muffler - 10 dBA Attenuation