DE350S GC Generator Set
- new - Products
- DE350S GC Generator Set
At a glance data:
Maximum Rating:
350 ekW
Minimum Rating:
350 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
350 ekW
Minimum Rating:
350 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
C9.3B ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore:
4.53in
Stroke:
5.87in
Displacement:
567.5in³
Compression Ratio:
16.5:1
Aspiration:
Air to Air Aftercooled
Fuel System:
Direct Injection
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Maximum:
186.7in
Width - Maximum:
79.3in
Height - Maximum:
84in
Standard Equipment
engine
- C9.3B, Inline 6 cylinder, 4 stroke diesel
air, cooling & exhaust
- Standard air filter
genset control
- GCCP 1.1
governor
- Adem A4
alternator
- A Frame standard alternator
fuel storage
- Single wall 8 hour fuel tank
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
air, cooling & exhaust
- 6" Elbow kit
- No muffler
- Single stage air filter
- 6" Elbow kit
- 5" Muffler - 10 dBA Attenuation
- 5-6" Exhaust adapter
- Dual element air filter
- 6" Muffler - 25 dBA attenuation
- 5" Elbow kit
- Canopy silencer
alternator requirements
- IP Standard @ 21 FUW A-Frame
- Space heater
auxiliary supply voltage
- 240V
certification
- Australia, CIS, Gulf Certification
- Certificate of Conformance 13
circuit breaker
- 4 Pole Circuit breaker 800A
- 4 Pole Circuit breaker 1250A
- Shunt Trip
- Neutral earth link
- 3 Pole Circuit breaker 630A
- 3 Pole Circuit breaker 800A
- Circuit breaker padlock
- 4 Pole Circuit breaker 630A
- 3 Pole Circuit breaker 1250A
- Overload via alarm switch on breaker
- Auxiliary contacts
enclosure
- Cat GC enclosure
fuel storage
- Low fuel level alarm
- High fuel level alarm
- Fuel level sender
- Dual wall 8 hour fuel tank
- Low fuel level shutdown
- Single wall tank with containment 01
genset control
- Coolant heater
- PLG Cellular 4G E
- Battery charger
- PLG Ethernet
- Standby Pack (Smart Jacket water heater, Battery charger)
- Oil temperature displays
- Low coolant temperature alarm
- Voltage adjust potentiometer
- Speed adjust potentiometer
- PLG Cellular 4G U
- Battery
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
350 ekW
Minimum Rating:
350 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts
C9 Generator Set
Maximum Rating:
350 ekW
Minimum Rating:
350 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
350 ekW
Minimum Rating:
350 ekW
Emissions/Fuel Strategy:
Low Fuel, R96/EUIIIa
Voltage:
220 to 480 Volts