DE450 GC (50 Hz) Generator Set
- new - Products
- DE450 GC (50 Hz) Generator Set
At a glance data:
Maximum Rating:
450 kVA
Minimum Rating:
450 kVA
Emissions/Fuel Strategy:
Non Regulated
Voltage:
380 to 415 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
450 kVA
Minimum Rating:
450 kVA
Emissions/Fuel Strategy:
Non Regulated
Voltage:
380 to 415 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby
Engine Specifications
Engine Model:
C13 In-line 6, 4-cycle diesel
Bore:
5.1in
Stroke:
6.2in
Displacement:
763in³
Compression Ratio:
15.8:1
Aspiration:
Turbocharged Air-to-Air Aftercooled
Fuel System:
EUI
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Maximum:
122in
Width - Maximum:
52.7in
Height - Maximum:
83.4in
Dry Weight - Genset (maximum):
6402lb
Standard Equipment
engine
- Cat® C13 Inline 6 cylinder, 4 stroke diesel
control panels
- GCCP 1.1
governor
- Mechanical governor
alternator
- A Frame standard alternator
fuel storage
- Single wall 8 hour fuel tank
cooling system
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
electrical options
- 3 Pole Circuit breaker
- Neutral earth link
- 24 Volt battery with rack and cables
air inlet system
- Air cleaner; light duty with disposable element
lube system
- Lubricating oil
- Oil drain line with valve
mounting system
- Captive linear vibration isolators
- Lifting provision and drag points
general
- Engine and alternator pre paint, Caterpillar yellow
Optional Equipment
control panel
- Speed and Voltage adjust potentiometers
- PLG 4G/3G/Ethernet
- Annunciator
- Emergency E-Stop
enclosure
- Cat GC enclosure
electrical options
- 4 Pole Circuit breaker
- Auxiliary contacts
- Padlockable circuit breaker
- Battery charger
- Wet battery
alternator
- Space heater
- AVR
fuel system
- Dual wall 8 hour fuel tank
- Single wall 8 hour fuel tank with spill containment
- Low fuel level shutdown
- Low and high fuel level alarms
exhaust system
- Industrial silencer
- 10 dBA Attenuation silencer
air inlet system
- Single stage air filter
- Dual element air filter
certifications
- EU Certificate of Conformance (CE)
- EAC Certification
extended service coverage
- 3, 4, 5 and 10 Years
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
450 kVA
Minimum Rating:
450 kVA
Emissions/Fuel Strategy:
Non Regulated
Voltage:
380 to 415 Volts
C9 Generator Set
Maximum Rating:
450 kVA
Minimum Rating:
450 kVA
Emissions/Fuel Strategy:
Non Regulated
Voltage:
380 to 415 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
450 kVA
Minimum Rating:
450 kVA
Emissions/Fuel Strategy:
Non Regulated
Voltage:
380 to 415 Volts