3412C | 800 kVA 50Hz Generator Set
- new - Products
- 3412C | 800 kVA 50Hz Generator Set
At a glance data:
Maximum Rating:
680 kVA
Minimum Rating:
680 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 415 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
680 kVA
Minimum Rating:
680 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 415 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore:
5.4in
Stroke:
6in
Displacement:
1648.86in
Compression Ratio:
13:01
Aspiration:
Turbocharged, Air to Air Aftercooled
Fuel System:
Pump and Lines
Governor Type:
ADEM™ A5
Generator Set Dimensions
Length - Maximum:
162.4in
Width - Minimum:
75in
Width - Maximum:
78.3in
Height - Maximum:
75in
Dry Weight - Genset (minimum):
12039lb
Dry Weight - Genset (maximum):
13030lb
Standard Equipment
air inlet system
- Air cleaner, single element canister type with service indicator
control panel
- GCCP Control panel
- DC volts
- Environmental sealed front face
- kVA (per phase, average & percent)
- Voltage adjust
- Compatible with the following optional modules:
- Low coolant level
- RPM
- Engine cycle crank
- Over/under frequency (81 o/u)
- Programmable protective relaying functions:
- kVAr (per phase, average & percent)
- coolant temperature
- Local annunciator
- Reverse reactive power (kVAr) (32RV)
- 2 Programmable digital outputs
- Emergency stop
- Amps (per phase & average)
- Volts (L-L & L-N)
- Failure to start (overcrank)
- Speed adjust
- 24 Volt DC operation
- Remote Serial annunciator
- kW (per phase, average & percent)
- Low coolant temperature
- High coolant temperature
- Over/under voltage (27 / 59)
- Reverse power (kW) (32)
- Run/auto/ stop/control
- Operating hours
- Customer data link (Modbus RTU)
- Power factor (per phase & average)
- Generator temperature monitoring module
- 6 programmable digital inputs
- Overspeed
- Text alarm/event descriptions
- 4 programmable relay outputs (Form A)
- kW-hr (total)
- Features include:
- Remote CAN annunciator
- Digital I/O module
- Generator phase sequence
- Low oil pressure
- Warning/shutdown with common LED indication of shutdowns for:
- Accessory module data link
- Emergency stop pushbutton
- Serial annunciator module data link
- Frequency (Hz)
- 2 Programmable relay outputs (Form C)
- Oil pressure (psi, kPa or bar)
- Digital indication for:
- Communications
- Overcurrent (50 / 51)
cooling system
- Caterpillar extended life coolant
- Coolant level shutdown
- Radiator with guard (Sized for 50 degrees C)
- Fan and belt guards
- Coolant drain line with valve, piped to edge of base
exhaust system
- Stainless steel exhaust flex with ANSI style outlet flange, gasket, bolts and mating weld flange, shipped loose
fuel system
- Water seperator
- Flexible fuel lines terminated on base
- Primary and Secondary fuel filters
- Fuel priming pump
generator and attachments
- Class H insulation
- 2:1 Volts/Hz
- 3-phase sensing
- Class F temperature rise
- 12 Leads
- VR6 voltage regulator
- Busbar termination
- Reactive droop
- SR4B self excited
governing system
- Cat electronic governor
lube system
- Lubricating oil
- Oil drain line with valve, piped to edge of base
- Fumes disposal, piped to front of radiator
- Oil filter
mounting system
- Base, formed steel with linear vibration isolators between base and engine-generator
starting / charging system
- 45 amp Charging alternator
- Fuel shutoff solenoid
- Battery with rack, cables
- 24 volt starting motor
Optional Equipment
air inlet system
- Heavy duty air cleaners
- Open element air cleaners
- Dual element air cleaners
circuit breakers
- 1600 Amp, 3 pole, Non-UL, 100% rated, 24 volt DC shunt trip
- 1250, 1600 Amp, 3 pole, IEC 100% rated, 24 volt DC shunt trip
control panel
- GCCP Control panel
- Vandal proof panel door
- Remote custom annunicator
- Ground fault relay
- Common alarm/shutdown relay
- Generator running VFC
- GCCP Control panel
- Local discrete I/O package
- First local annunicators
- Generator temperature monitoring package
cooling system
- Jacket water heaters
- Radiator duct flange
european certifications
- Eurasian Conformity (EAC) mark
exhaust system
- Through wall installation kit
- Manifold and turbocharger guards
- Elbow kit
- Mufflers
generator and attachments
- Digital voltage regulator
- Oversize and premium generators
- Permanent magnet excitation (PMG)
- Space heater
lube system
- Manual sump pump
mounting system
- Fuel tank base (1200 ltr)
special tests / reports
- PGS Test report @ 0.8 power factor
- PGS Test report @ 1.0 power factor
starting / charging
- Battery disconnect switch
- Oversize batteries
- Battery chargers
- Heavy duty starting system
governing system
- Electronic load share
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
680 kVA
Minimum Rating:
680 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 415 Volts
C9 Generator Set
Maximum Rating:
680 kVA
Minimum Rating:
680 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 415 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
680 kVA
Minimum Rating:
680 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 415 Volts