C32 | 1250 kVA 50 Hz Generator Set
- new - Products
- C32 | 1250 kVA 50 Hz Generator Set
At a glance data:
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.Producing reliable power from 910 kVA to 1500 kVA at 50 Hz, our C32 diesel generator sets are made to meet your mission critical, continuous, standby and prime applications. We've designed each to ISO 8528-5 transient response requirements and to accept 100 percent rated load in one step. Generator sets range from low fuel consumption to low emissions systems. Seismic certification is also available for select models, ensuring you maintain power after unexpected disturbances. Our integrated control system, including ATS and switchgear, protects your power supply and keeps you connected through on-site and remote monitoring options. We offer easy-to-use EMCP control panel options, combining your management and diagnostic tools in one. The EMCP 4.4 controller provides multi-generator set paralleling capability, giving you the ability to add generator sets to match your growing power requirements. Browse a broad range of accessories and bolt-on system expansion attachments. Find flexible packaging to fit unique spatial requirements and environmental conditions. Our C32 generator sets are made for demands, so you can make yours.
Generator Set Specifications
Engine Specifications
Generator Set Dimensions
Standard Equipment
air inlet system
- Single element canister type with service indicator
control panel
- GCCP Control panel
- Control features
- Programmable protective relaying functions
- Digital indicators
- Warning shutdowns
- Communications
cooling system
- Fan and belt guards
- Radiator fan and fan drive
- ATAAC
- Coolant drain line with valve
- Caterpillar extended life coolant
- Low coolant level sensor
exhaust
- Exhaust manifold - dry
- 203 mm (8 in) ID round flanged outlet
fuel system
- Primary fuel filter with water separator
- Fuel priming pump
- Secondary fuel filters
- Fuel cooler
generators and attachments
- Integrated voltage regulator (IVR)
- Permanent magnet excitation (PMG)
- 3 Phase brushless
- Reactive droop
- Internal excitation (IE)
- NEMA Class H insulation
- Class H temperature rise at 40C ambient
- Salient pole
- Winding temperature detectors
- 6 Lead
- IEC standard hole pattern
- Busbar connections, top center mounted, top cable entry
governing system
- ADEM(tm) A4
mounting system
- Rails - engine/generator/radiator mounting
- Rubber anti-vibration mounts
lube system
- Oil drain lines and valve
- Integral lube Oil cooler
- Fumes disposal
- Lubricating oil
- Oil filter, filler and dipstick
- Gear type lube oil pump
power termination
- Busbar
starting / charging system
- 24 Volt electric starting motor
- Battery, rack and cables
- Battery disconnect switch
- 45 Amp Charging alternator
general
- Caterpillar yellow with high gloss black rails & radiator
- RH service
- Flywheel and flywheel housing-SAE
- SAE standard rotation
Optional Equipment
air inlet system
- Dual element air cleaner
- Heavy duty air cleaner
- Standard air cleaners
circuit breakers
- 1600, 2000, 2500 and 3200 Amp, 3 Pole, IEC-Rated Circuit breakers
- Enclosures - Control packaging
- Cable supports
- Center posts busbars
- Circuit breaker wiring groups
- Power connection covers
- Shrouds
- 400, 800, 1200, 1600, 2000, 2500 and 3000 Amp, 3 Pole, UL-100% Rated Circuit breakers
- 800, 1600, 2000, 2500 and 3200 Amp, 4 Pole, IEC rated Circuit breakers
control panels
- GCCP Control panel
cooling system
- Radiator duct flange
- Certified radiator
- High ambient radiator
- Standard radiator
- Extended life coolant
enclosures
- Enclosure fuel tank options
- Sound attenuated enclosure
- Enclosure louvres - fixed and motorized
- Color options
- AC Panel, outlets and lights
- Premium sound attenuated enclosure
- Cold weather bundle
- Panel bracket
- DC lighting package
exhaust system
- Exhaust through the wall kit
- Flange and exhaust expanders
- Flanges
- Guard and shield system
- All C32 engines have 203 mm (8 in) exhaust outlets
- Elbow mounting kit
- Mufflers
- Flexible fittings
generator and attachments
- Low voltage generators
- Medium voltage generators
lube system
- Oil pan
- Prelube manual sump pump
- Oil level regulator
mounting system
- IBC vibration isolators
- Mounting base types
- Spring type vibration isolators
- Standard package isolators
power termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
power connections
- Low voltage connection cables
- Neutral grounding connection
- Center post busbars
starting / charging system
- 10 Amp enclosure Battery charger
- Space heater
- 10 Amp Battery charger
- 20 Amp Battery charger
- 35 Amp Battery charger
- Electric starting motor - Standard/heavy duty
- Standard 24 volt open package battery set - Dry
- Jacket water heater
special tests / reports
- PGS Test report @ 1.0 power factor
- Standard engine test
- Generator test report
- Custom generator TVA report
- PGS Test report @ 0.8 power factor
- CSA test and certification
- IBC seismic Certifications
- Standard genset Torsional Vibration Analysis (TVA) report
- OSHPD seismic Certifications
general
- Special paint
- US aid emblem