Skip to content

3516E Low Voltage Generator Set

At a glance data:

Standby Rating:
2750 ekW
Prime Power Rating:
2500 ekW
Emissions/Fuel Strategy:
Tier 2, Low NOx
Voltage:
416 to 13,800 Volts
3516E 2750 ekW

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Standby Rating:
2750 ekW
Prime Power Rating:
2500 ekW
Emissions/Fuel Strategy:
Tier 2, Low NOx
Voltage:
416 to 13,800 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Mission Critical, Prime
Maximum Rating:
2750 ekW
Minimum Rating:
2500 ekW

Engine Specifications

Engine Model:
3516E, V-16, 4-Stroke, Water-Cooled Diesel
Bore:
6.69in
Stroke:
8.47in
Displacement:
4765in³
Compression Ratio:
14.7:1
Aspiration:
ATAAC
Fuel System:
EUI
Governor Type:
Adem™ A5

Generator Set Dimensions

Length - Maximum:
303.3in
Width - Maximum:
104.0in
Height - Maximum:
131.6in
Dry Weight - Genset (maximum):
40750lb

Standard Equipment

air inlet system

  • Single element canister type with service indicator
  • Air cleaner

cooling

  • Package mounted radiator

exhaust

  • Exhaust flange outlet

fuel

  • Primary fuel filter with integral water separator
  • Fuel priming pump

generator

  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines

power termination

  • Busbar

starting/charging

  • Heavy duty starting system
  • Charging alternator

control panel

  • Communications:
  • 6 Programmable digital inputs
  • Programmable protective relaying functions:
  • Low oil pressure
  • Environmental sealed front face
  • Volts (L-L & L-N)
  • Emergency stop pushbutton
  • Serial annunciator module data link
  • Reverse power (kW) (32)
  • Engine cycle crank
  • Lamp test
  • Over/under frequency (81 o/u)
  • kW-hr (total)
  • Speed adjust
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Engine cool-down timer
  • Overcurrent (50/51)
  • Reverse reactive power (kVAr) (32RV)
  • kW (per phase, average & percent)
  • kVAr-hr (total)
  • Generator phase sequence
  • Oil pressure (psi, kPa or bar)
  • Low coolant temperature
  • Amps (per phase & average)
  • Generator mounted - rear facing
  • Over/under voltage (27/59)
  • Low coolant level
  • Accessory module data link
  • kVAr (per phase, average & percent)
  • Cat ECS controller includes:
  • Failure to start (overcrank)
  • 2 Programmable relay outputs (Form C)
  • Cat ECS 100
  • Overspeed
  • 2 Programmable digital outputs
  • DC volts
  • Frequency (Hz)
  • High coolant temperature
  • Warning/shutdown with common LED indication of shutdowns for:
  • Operating hours
  • 4 Programmable relay outputs (Form A)
  • Coolant temperature
  • Power factor (per phase & average)
  • Digital indication for:
  • Panel lights
  • Text alarm/event descriptions
  • Controls:
  • 24 Volt DC operation
  • Alarm acknowledge
  • Customer data link (Modbus RTU)
  • kVA (per phase, average & percent)

cooling system

  • Caterpillar extended life coolant
  • Coolant drain line with valve
  • Coolant level sensors
  • JWAC
  • Radiator fan and fan drive
  • Fan and belt guards

exhaust system

  • Dry exhaust manifold
  • Flanged faced outlet(s)

fuel system

  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Fuel cooler; not included with packages without radiator
  • Fuel priming pump

generators and attachments

  • Form wound
  • 3 Phase brushless, Salient pole
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • Winding temperature detectors
  • Permanent magnet excitation (PMG)
  • Anti-condensation space heater
  • Right side extension terminal box, busbar connections, top mounted, bottom cable entry
  • 6 Lead
  • NEMA standard hole pattern

governing system

  • ADEM III

literature

  • Parts book
  • Operation & Maintenance Manual

lube system

  • Integral lube Oil cooler
  • Fumes disposal
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Lubricating oil
  • Gear type lube oil pump

mounting system

  • Rubber anti-vibration mounts - shipped loose
  • Rails - engine/generator/radiator mounting

starting / charging system

  • Battery disconnect switch
  • 45 Amp Charging alternator
  • Battery and battery rack w/cables
  • 24 Volt electric starting motor

general

  • Flywheel and flywheel housing-SAE No. 00
  • SAE standard rotation
  • Paint - Caterpillar yellow with high gloss black rails & radiator
  • Right hand servicing

Optional Equipment

air inlet system

  • Air inlet protection
  • Remote air inlet adapters
  • Dual element air cleaners
  • Heavy duty air cleaners

circuit breakers

  • Busbar connections
  • P Frame breaker connections
  • R Frame breaker connections
  • Optional busbar power connections
  • Circuit breaker harnesses
  • Masterpact breaker connections
  • Cable entry options
  • 2000, 2500, 3200, 4000 Amp, 4 Pole, IEC rated Circuit breakers
  • 2000, 2500, 3200, 4000, 5000 Amp, 3 Pole, IEC rated Circuit breakers
  • 1600, 2000, 2500, 3000, 4000, 5000 Amp, 3 Pole, UL-100% rated Circuit breakers

power termination

  • Circuit breakers, IEC compliant

control panel

  • Customer interface options
  • Mounting group - External box clips
  • EMCP 4.4
  • PC monitoring (Remote and local)
  • Ground
  • Load share module options
  • Annunciator modules
  • Auxiliary box
  • Language options
  • Remote speed adjust
  • Vandal proof panel door
  • Voltage raise/lower switch
  • Generator temperature monitoring

cooling system

  • Expansion tanks
  • Optional Serpentine radiators
  • Water level switch gauges
  • Optional ATAAC radiators

exhaust system

  • Flexible fittings
  • Elbows
  • Flanges and exhaust fittings
  • Flanges
  • Y Adapters
  • Mufflers

fuel system

  • Duplex fuel filters
  • Primary fuel filters

generators and attachments

  • Differential current transformers - 8.7 and 15 kV class
  • Alternator air cleaners

instrumentation

  • Pyrometer and thermocouples

lube system

  • Manual prelube pump
  • Lube oil in standard sump
  • Oil level regulator
  • Electric prelube pumps

mounting system

  • Spring type vibration isolators
  • IBC Seismic vibration isolators NORAD
  • Puck style low efficiency lsolators

power connections

  • Neutral ground connections
  • 2700 & 3000 Frame
  • Grounding groups

special tests / reports

  • IBC Certifications
  • Generator set test report
  • Torsional vibration analysis
  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • Standard engine test charge
  • Fuel consumption test
  • Generator set consumption test

starting / charging system

  • Starter cover
  • Electric starting motors
  • Air pressure regulator
  • 24 Volt battery set - Dry
  • Jacket water heaters
  • Engine barring group
  • 10, 20, 35 and 50 Amp Battery chargers
  • Air starting motors

general

  • Special paint colors
  • US aid emblem