3512B Diesel Generator Set

At a glance data:

Standby Rating:
1875/1750 kVA
Prime Power Rating:
1700/1600 kVA
Emissions/Fuel Strategy:
Low Fuel , Low Emissions
Voltage:
400 to 415 Volts

Overview

1600 - 1875 kVA at 50 Hz Diesel Genset
The 3512B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.
Q. Does this generator comply with ISO 8528 guidelines?
A. Yes, the 3512B, like all of our generators, is tested in accordnace the load steps outlined in with ISO 8528, Part 5.

Generator Set Specifications

Standby Rating:
1875/1750 kVA
Prime Power Rating:
1700/1600 kVA
Emissions/Fuel Strategy:
Low Fuel , Low Emissions
Voltage:
400 to 415 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby, Mission Critical, Prime, Continuous
Minimum Rating:
1600 kVA
Maximum Rating:
1875 kVA

Engine Specifications

Engine Model:
3512B TA, V-12, 4-Stroke Water-Cooled Diesel
Bore:
6.69in
Stroke:
7.48in
Stroke - HD:
8.46in
Displacement:
3161.03in³
Displacement - HD:
3576in³
Compression Ratio:
15.5:1 HD
Aspiration:
TA
Fuel System:
Electronic Unit Injection
Governor Type:
ADEM™ A3

Generator Set Dimensions

Length - Minimum:
212.8in
Length - Maximum:
217.1in
Width - Minimum:
90in
Width - Maximum:
90in
Height - Minimum:
94.9in
Height - Maximum:
94.9in
Dry Weight - Genset (minimum):
25620lb
Dry Weight - Genset (maximum):
26530lb

Standard Equipment

control system

  • EMCP 4.2B
  • Emergency stop pushbutton
  • Failure to start (overcrank)
  • High coolant temperature
  • 4 Programmable digital outputs
  • Auto/start/stop control
  • 4 Programmable digital inputs
  • DC volts
  • Engine cycle crank
  • Low coolant level
  • Speed adjust
  • Low oil pressure
  • Communications
  • Frequency (Hz)
  • Warnings/shutdown indicators
  • Engine cool-down timer
  • Operating hours
  • Emergency stop
  • Oil pressure
  • Lamp test
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Digital indication for:
  • Overspeed
  • Alarm acknowledge
  • RPM
  • 24 Volt DC operation
  • Amps (per phase & average)
  • Coolant temperature
  • Volts (L-L & L-N)

governing system

  • ADEM III

cooling system

  • SCAC
  • Coolant drain line with valve
  • Radiator fan and fan drive
  • Fan and belt guards
  • Coolant level sensors
  • Caterpillar extended life coolant

exhaust system

  • Dry exhaust manifold
  • Flanged faced outlet(s)

fuel system

  • Fuel cooler; not included with packages without radiator
  • Flexible fuel lines
  • Secondary fuel filters.
  • Fuel priming pump

generator system

  • RFI suppression
  • Min / max exciter
  • 3 phase brushless, Salient pole
  • Caterpillar's digital voltage regulator (CDVR)
  • Class H temperature rise at 40C ambient
  • Random wound
  • Winding temperature detectors
  • Internal excitation (IE)
  • 3 Phase voltage sensing
  • Busbar connections
  • 6 Leads
  • NEMA Class H insulation

literature

  • Parts book
  • Operation & Maintenance Manual

lube system

  • Lubricating oil
  • Gear type lube oil pump
  • Fumes disposal
  • Oil drain lines and valve
  • Oil filter, filler and dipstick
  • Integral lube Oil cooler

mounting system

  • Rails - Engine/generator/radiator mounting

general

  • Flywheel and Flywheel housing-SAE
  • Caterpillar yellow with high gloss black rails & radiator
  • RH service
  • SAE standard rotation

Optional Equipment

air inlet system

  • Dual element air cleaner
  • Single element filter
  • Heavy duty air cleaner

exhaust

  • Exhaust mufflers

generator

  • Internal excitation (IE)
  • Oversize and premium generators
  • Anti-condensation heater
  • Permanent magnet excitation (PMG)

control system

  • EMCP voltage and current sensing groups
  • CAN2 network equipment
  • Annunciator modules (Local and remote)
  • Customer interface options
  • Load share module options (LV)
  • EMCP 4.3, EMCP 4.4
  • Annunciator network equipment
  • Neutral to ground connection
  • Generator temperature monitoring
  • Remote annunciator module (Low voltage)
  • Local annunciator modules (Low voltage)
  • Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
  • Governors (MUI-Low voltage)

power termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

cooling system

  • Installed radiators
  • Coolant
  • Water level switch gauges
  • Cooling system attachments

mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

starting/charging

  • Jacket water heater
  • Oversize batteries
  • Battery chargers
  • Charging alternator
  • Heavy duty starting system
  • Air starting motor with control and silencer

exhaust system

  • Flexible fittings
  • Mufflers
  • Y Adapters
  • Elbows
  • Flange and exhaust expanders

factory support

  • Factory commissioning

fuel system

  • Secondary fuel filters
  • Primary fuel filter

generators and attachments

  • Internally excitation
  • Permanent magnet excitation (PMG)
  • RW
  • 6 Leads
  • Space heater kit
  • 1400 and 1600 Frame
  • Pitch 0.6667
  • Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
  • Generator conversion kits - PM to IE / IE to PM

general

  • EU Certificate of Conformance (CE)
  • The following options are based on regional and product configuration:
  • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
  • UL 2200 package

instrumentation

  • Pyrometer and thermocouples

lube system

  • Lube oil in standard sump
  • Standard sump oil pan
  • Lube oil filters
  • Drain GP oil pan
  • Oil level regulator
  • Prelube pump groups

crankcase system

  • Crankcase protection group
  • Crankcase ventilation system

mounting system

  • Low efficiency isolators
  • Low efficiency isolators puck
  • Low isolators
  • Spring type vibration isolators

power connections

  • Low voltage - Power connection options
  • Electrically operated circuit breakers
  • Low voltage - Package mounted circuit breakers
  • Low voltage - 1400 and 1600 Frame generators

special tests / reports

  • Custom generator TVA report
  • PGS Test report @ 1.0 power factor
  • Generator fuel consumption test
  • Standard generator TVA report
  • PGS Test report @ 0.8 power factor
  • Generator test report
  • Standard engine test charge

starting / charging system

  • 20 Amp Battery charger
  • 10 Amp Battery charger
  • Electric starting motors
  • Starter cover
  • Batteries, racks and cables
  • Jacket water heater wiring groups
  • Jacket water heaters
  • 35 Amp Battery charger

extended service coverage

  • Gold - 36,48, 60, 120 month coverage
  • Cat branded commercial power system
  • Silver - 36 ,48, 60, 120 month coverage
  • Platinum - 24, 36, 48, 60, 120 month coverage