G3520 2000kW Gas Generator Set

At a glance data:

Gas Standby Rating:
2000 ekW @ 0.8pf
Fuel Type:
Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy:
U.S. EPA Stationary Non-Emergency Certified
Frequency:
60 Hz

Overview

Generator Set Specifications

Gas Standby Rating:
2000 ekW @ 0.8pf
Fuel Type:
Natural Gas, Hydrogen Blend (up to 5%)
Emissions/Fuel Strategy:
U.S. EPA Stationary Non-Emergency Certified
Frequency:
60 Hz
RPM:
1800 rpm

Engine Specifications

Engine Model:
G3520
Displacement:
5956in³
Aspiration:
TA
Bore:
6.7in
Stroke:
8.5in

Generator Set Specifications

Compression Ratio:
11.5

Generator Set Dimensions

Length:
336in
Width:
94in
Height:
128in
Weight:
48500lb

Standard Equipment

air inlet

  • Two-element single-stage air cleaner with enclosure and service indicator

control panel

  • Cat ECS 100

cooling

  • Jacket water and SCAC engine-driven pumps
  • Jacket water and SCAC thermostats

exhaust

  • Dry exhaust manifolds, insulated and shielded
  • Cat-flanged face outlet on turbocharger
  • Individual exhaust port and turbocharger outlet wired to integrated temperature sensing module (ITSM) with GCEM providing alarms and shutdowns

fuel system

  • Fuel system is sized for 31.5 to 47.2 MJ/NM3 dry pipeline natural gas with pressure of 10.2 to 34.5KPa to the engine fuel control valve
  • Engine-installed electronic control valve
  • Gas pressure regulator
  • Throttle plate, 24V DC actuator, controlled by GECM
  • 24V DC energized-to-run (ETR) gas shutoff valve

general

  • Parts book
  • Paint- Caterpillar Yellow with high gloss black rails and radiator
  • Operation and maintenance manuals
  • Crankshaft vibration damper and guard
  • RH Service

generator

  • Permanent Magnet Excitiation
  • Integrated voltage regulator (IVR)
  • SR5
  • Winding temperature detectors
  • Anti-condensation space heater
  • NEMA Class H insulation

starting/charging

  • 24V starting motors
  • Battery with cables and rack (shipped loose)
  • Jacket water heater
  • Electric Starter

governing system

  • ADEM A4

ignition system

  • Electronic Ignition System (controlled by ADEM A4)
  • Individual Cylinder Detonation Sensitive Timing (DST)

Optional Equipment

air inlet

  • Air cleaner with precleaner

control panel

  • EMCP 4.4
  • Local alarm module
  • Engine failure relay
  • Remote annunciator
  • Remote PC monitoring
  • Local PC monitoring

circuit breakers

  • 1600A, 2000A 3 Pole, UL-100% Rated R-Frame Circuit Breakers
  • 100% rated, 3-pole (UL/CSA/IEC) 5th Digit Rating
  • S LSI, G LSIG, P LSIG-P, 4th Digit Type
  • Frame mounting
  • 3-pole (IEC 947-2 rated)
  • 2000A, 2500A, 3000A 3 Pole, UL-100% Rated Masterpact Circuit Breakers

cooling

  • Package mounted radiator
  • Coolant level drain line with valves, fan with guard

exhaust

  • 18, 25 dBA Attenuation
  • 305mm (12 in) spark arresting muffler
  • 305 mm (12in.) elbow
  • 305 mm (12 in.) flange
  • 305 mm (12 in.) muffler

fuel system

  • 3, 0-100 kPag, 4-20mA gas train pressure sensors

general

  • Digital diagnostic tool

generator

  • Bearing temperature detectors
  • Generator air filter
  • Cable access box
  • European bus bars
  • Low voltage extension box

starting/charging

  • 20A, 24VDC battery charger
  • 45A, 24V charging alternator (requires engine driven pumps)

grid code compliance

  • 60 Hz: USA