At a glance data:
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
Frequency:
50 Hz
Speed:
1500
Duty Cycle:
Standby, Prime
Engine Specifications
Engine Model:
C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore:
5.71in
Stroke:
7.2in
Displacement:
1106.4in³
Compression Ratio:
14.5:1
Aspiration:
Air to Air Aftercooled
Fuel System:
Electronic unit injection
Governor Type:
Adem™A4
Generator Set Dimensions
Length - Maximum:
162.4in
Width - Maximum:
78.3in
Height - Maximum:
75in
Standard Equipment
air inlet system
- Single element air cleaner
- Turbocharger
- Aftercooler core
- Light duty air cleaner
control system
- GCCP 1.3
cooling
- Coolant drain line with valve
- Radiator and cooling fan with guard
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
exhaust system
- Stainless steel exhaust flex gaskets, raincap and SAE exhaust flange for customer use - shipped loose
fuel system
- Standard 8 hour open set integral fuel tank
generator and attachments
- LC frame generator - IP23 Protection
- Matched to the performance and output characteristics of Cat engines
- Segregated low voltage (AC/DC) wiring panel
- Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
- Integrated voltage regulator (IVR)
- Power center, IP22
- Integrated voltage regulator (IVR)
governing system
- Cat electronic governor (ADEM A4)
lube system
- Lubricating oil
- Oil drain lines with valves
mounting system
- Captive linear vibration isolators between base and engine-generator.
starting/charging
- 24 Volt battery with rack and cables
general
- Engine and alternator pre-paint, Caterpillar yellow
Optional Equipment
air inlet system
- Dual element air cleaner
circuit breakers
- 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
- Circuit breaker (IEC) Auxiliary contacts
- 3 Pole (IEC-100% rated) Circuit breakers - Motorised
- Padlockable circuit breaker device
- Shunt trip for IEC breaker
- Power terminal strip
- 4 Pole (IEC-100% rated) Circuit breakers - Motorised
- 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
control system
- Local alarm horn
- Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
- GCCP 1.4
- Remote annunciator module
- Oil temperature displays
- Local alarm modules
cooling system
- Radiator transition flange
- Low coolant temperature alarm
enclosures
- Sound attenuated enclosures (to be available soon)
exhaust system
- 8 and 10 inch elbow kits
- 10, 25, 35 dB end in / end out mufflers
- Engine mounted muffler
- 8 and 10 inch GP flanges
- Manifold and turbocharger guards
fuel system
- Integral - Dual wall fuel tank base
- Fuel transfer system
- Manual fuel transfer pump
generator and attachments
- Space heaters
- A Frame CIP generator
- LC frame CIP generator
- A Frame oversize generator
- Ingress protection
- LC frame oversize generators
- LC frame generator
- Permanent magnet excitation (PMG)
lube system
- Manual sump pump
starting and charging
- Jacket water heaters
- 5 Amp Battery charger
- Battery disconnect switch
- Jacket water heaters
C18 Sound Attenuated Enclosure 50 and 60 Hz
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
C13, C15, C18 SA enclosure. 350-600 kW 60 Hz
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
C13, C15, C18 WP Enclosure. 350-600 kW 60 Hz
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
C18 High Ambient Acoustic Enclosure
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
C9 Generator Set
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
850 kVA
Minimum Rating:
706 kVA
Emissions/Fuel Strategy:
Low Fuel
Voltage:
380 to 415 Volts