C175-16 Generator Set
- new - Products
- C175-16 Generator Set
At a glance data:
Standby Rating:
3100(no fan)/3000 kVA
Prime Power Rating:
2825(no fan)/2725 kVA
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 11000 Volts
Print
Electric Power Rating Guide
C175-16, 50 Hz, 3000 kVA Standby/MC, 2725 kVA Prime, 2500 kVA Cont., Low Fuel Consumption / Low Emissions (with fan) Spec Sheet
C175-16, 50 Hz, 3100 kVA Standby/MC, 2825 kVA Prime, 2600 kVA Cont., Low Fuel Consumption / Low Emissions (without fan) Spec Sheet
C175-16, 50 Hz, 2725 kVA, Prime-DCP, Low Fuel Consumption (with fan) Spec Sheet
C175-16, 50 Hz, 2825 kVA, Prime-DCP, Low Fuel Consumption (without fan) Spec Sheet
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Standby Rating:
3100(no fan)/3000 kVA
Prime Power Rating:
2825(no fan)/2725 kVA
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 11000 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby, Mission Critical, Prime, Continuous
Maximum Rating:
3100 kVA
Minimum Rating:
2500 kVA
Engine Specifications
Engine Model:
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore:
6.89in
Stroke:
8.66in
Displacement:
5166.88in³
Compression Ratio:
16.7:1
Aspiration:
Turbo Aftercooled
Fuel System:
Common Rail
Governor Type:
ADEM� A4
Generator Set Dimensions
Length - Minimum:
241.6in
Length - Maximum:
311in
Width - Minimum:
83in
Width - Maximum:
108.5in
Height - Minimum:
87in
Height - Maximum:
130.2in
Dry Weight - Genset (minimum):
42750lb
Dry Weight - Genset (maximum):
50750lb
Standard Equipment
air inlet system
- 4 x Single element canister with service indicator(s)
control panel
- Cat ECS 100
- Volts (L-L & L-N)
- Engine cycle crank
- Power factor (per phase & average)
- Overcurrent
- Communications
- Emergency stop
- 2 Programmable relay outputs (Form C)
- 6 Programmable digital inputs
- 2 Programmable digital outputs
- Environmental sealed front face.
- DC Volts
- Reverse power
- Programmable protective relaying functions
- High coolant temperature
- Accessory module data link
- Low coolant level
- Over/under frequency
- Amps (per phase & average)
- True RMS AC metering, 3-phase, +/-2% accuracy
- Low coolant temperature
- Reverse reactive power
- Controls
- Oil pressure (psi, kPa or bar)
- Lamp test
- Coolant temperature
- Warning/shutdown Indicators:
- 4 Programmable relay outputs (Form A)
- Alarm acknowledge
- Generator phase sequence
- 24 Volt DC operation
- Serial annunciator module data link
- Customer data link (Modbus RTU)
- Failure to start (overcrank)
- Auto/start/stop control.
- Low oil pressure
- RPM
- Text alarm/event descriptions.
- Digital Indicators
- Generator mounted - rear facing
- Emergency stop pushbutton
- Engine cool-down timer
- Operating hours
- Over/under voltage
- Overspeed
- Frequency (Hz)
cooling system
- Radiator group - shipped loose
- SCAC cooling
- Coolant Sensors
- Coolant drain line and valves
- Fan and belt guards
exhaust system
- Bolted flange, with bellow for each turbo
- Dry exhaust manifold
fuel system
- Filters x 3
- Secondary/ tertiary fuel filters
- 10 Micron spin On Type
- 4 Micron Spin On Type
- Primary fuel filter water/fuel water separator
- Engine mounted filters x 3
generator and attachments
- 6 Leads
- IEC platinum stator RTDs
- Voltage regulator
- Reactive droop capability
- 3 Phase voltage sensing
- RFI suppression
- Min / max exciter limiter
- exciter diode monitor
- Form wound
- Permanent magnet excitation (PMG)
- NEMA Class H insulation
- Class H temperature rise at 40C ambient
- (LV) Busbar connections, top/center mounted, top cable entry
- 3 Phase Brushless
- Salient pole
- 50 Hz models: IEC standard hole pattern
- (MV) Busbar connections, right side extension box, bottom cable entry
- Anti-condensation space heater
- Class F temperature rise at 40C ambient
- Right side extension box, bottom cable entry
governing system
- ADEM A4
- Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
lube system
- Gear type lube oil pump
- Lubricating oil
- Fumes disposal
- Integral lube Oil cooler
- Oil drain lines and valve
- Oil filter, filler and dipstick
- Prelube - required with prime, continuous, and standby
mounting systems
- Rubber anti-vibration mounts - shipped loose
- Battery disconnect switch
- Batteries and battery rack w/cables
- Dual 24 volt electric starting motors
- Rails - Engine/generator
service instructions
- Two PM inspections
power termination
- Busbar
general
- Paint - Caterpillar yellow with high gloss black rails & radiator
- Right hand servicing
- Flywheel and flywheel housing-SAE No. 00
- SAE standard rotation
Optional Equipment
air inlet system
- Single element air cleaner
- Dual element air cleaner
- Air inlet adapters
- Air inlet protection
control panel
- EMCP 4.4
- EMCP 4.4 optional harness
- Controller and MV&HV power connection locations
- Load share module
- Controller mounting location - LV / MV
- Customer AC-DC connection mounting location - LV/MV
- Load share module / auxiliary plate and auxiliary box (LV)
- Load share governor
- Frame boxes
- Automatically selected ground
- Controller voltage and current sensing groups
- Raise lower switch
- Speed adjust
- Annunciator modules
- Customer interface options
- Generator temperature monitoring
- Modbus monitoring of packages
- E-Stop
- Interconnect harness
- Generator harness
cooling system
- Package mounted radiator
- Remote radiators
- Fuel cooler
exhaust system
- Front housing - Standby or mission critical
- Front housing - Prime or continuous
- Exhaust collectors/manifold
- Exhaust support group
- Mufflers
- Weld flanges
- Aftercooler drain
crankcase systems
- Explosive relief valves
- Crankcase ventilation system
fuel system
- Primary fuel filter
generators and attachments
- Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
- Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
- Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
- Space heater kit
- Thermostat for space heater
- Conversion GP - Top cable entry
- Generator air intake
- Differential current transformers
instrumentation
- Pyrometer and thermocouples
lube system
- Lube oil heater
- Drain group oil pans
- Lubricating oil
- Electric prelube pumps
- Oil filters
mounting
- Rubber anti-vibration mounts
- Spring type linear vibration isolators
- IBC vibration isolators - Shipped loose
power connections
- Center post busbarss (LV)
- Side/rear mounted busbars (LV)
- Harnesses (Breaker)
- Cable entry options (LV)
- Enclosures - Control packaging (LV)
- Power connection covers (LV)
- Neutral ground (LV)
- 1800 Frame generators Circuit breaker
- Masterpack breakers
- Paralleling circuit breakers
- 1800 Frame generator side / rear mounted busbars (MV)
- Cable entry options (MV)
- Neutral ground (MV)
- Low voltage connection cable
- Masterpack breaker connections
special tests / reports
- Generator test report
- PGS Test report @ 1.0 power factor
- PGS Test report @ 0.8 power factor
- Standard genset TVA (Torsional Vibration Analysis) report
- Custom generator TVA report
- Special test charge - Engine only
- Genset fuel consumption test
- Standard engine test charge
- IBC seismic Certification
- OSCOSH1 seismic Certification
starting / charging system
- 24 Volt power distribution box
- 24 Volt electric starting motor
- Air starting motor
- Air pressure regulator
- Starter location covers
- 24 Volt battery set - Dry
- Heavy duty battery sets with rack
- 20 Amp Battery chargers
- 35 Amp Battery chargers
- 50 Amp Battery chargers
- Charging alternators - Dry
- Jacket water heaters
- Jacket water heater wiring groups
general
- Special paint colors
- Service tools - Engine barring group
- Barring group manual
- Engine barring air powered
- Control GP - air powered bar group
Similar Products
DE75AE0 (50 Hz) Generator Set
Standby Rating:
3100(no fan)/3000 kVA
Prime Power Rating:
2825(no fan)/2725 kVA
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 11000 Volts
C9 Generator Set
Standby Rating:
3100(no fan)/3000 kVA
Prime Power Rating:
2825(no fan)/2725 kVA
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 11000 Volts
DE165E0 (50 Hz) Generator Set
Standby Rating:
3100(no fan)/3000 kVA
Prime Power Rating:
2825(no fan)/2725 kVA
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 11000 Volts