3516B Diesel Generator Set with Dynamic Gas Blending
- new - Products
- 3516B Diesel Generator Set with Dynamic Gas Blending
At a glance data:
Maximum Rating:
1600 ekW (2000 kVA)
Minimum Rating:
1600 ekW (2000 kVA)
Emissions/Fuel Strategy:
Non-certified
Aspiration:
Turbocharged-Aftercooled
Overview
Producing oil and gas is a complex task that requires specialized power generation equipment. Cat 3500 generator sets with Dynamic Gas Blending offer the lowest owning and operating cost by displacing diesel with low cost gas. They are specifically designed for the oilfield and combine decades of experience in diesel and gas engines with the latest electronics to ensure highest performance, optimum dual fuel operation, low emissions, and simplified operator interface.Cat generator sets are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.3516B generator set with dynamic gas blending kit. Ratings: 1600 ekW (2000 kVA) @ 50 Hz (1500 rpm).
Engine Specifications
Maximum Rating:
1600 ekW (2000 kVA)
Minimum Rating:
1600 ekW (2000 kVA)
Emissions/Fuel Strategy:
Non-certified
Aspiration:
Turbocharged-Aftercooled
Manifold Type:
Dry
Bore:
6.69in
Stroke:
7.48in
Displacement:
4211.0in³
Engine Control and Protection:
ADEM A4
Generator Set Control:
EMCP 4.4
Generator:
SR4B
Fuel System:
EUI
Frequency - Speed:
50 Hz (1500 rpm)
Capacity for Liquids
Fuel:
CNG, LNG, field gas, natural gas with diesel
Lube Oil System - Refill:
107.0gal (US)
Cooling System - Engine:
62.0gal (US)
Dimensions
Length:
260.6in
Width:
94.4in
Height:
99.5in
Weight:
41888.0lb
Standard Equipment
air inlet system
- Aftercooler core — corrosion resistant
- Air cleaner — regular duty with soot filter
- Service indicators
- Flame arrestors
control system
- ADEM A4 ECU
- ISM (integrated sensor module) for combustion feedback sensors
- Exhaust gas temperature sensors
cooling system
- Radiator cooled - land based
- Outlet controlled thermostat and housing
- Jacket water pump — gear-driven
- Dual outlet
- Aftercooler cooling pump (SCAC) — gear-driven centrifugal
diesel fuel system
- Fuel filter
- Fuel transfer pump
- Flexible fuel lines
- Fuel priming pump
- Electronically controlled unit injectors
exhaust system
- Exhaust flexible fitting, adapter and flanges
- Dual turbochargers with water-cooled bearings
flywheel and flywheel housing
- SAE No. 00
- SAE standard rotation
gaseous fuel system
- Low pressure regulator
- Electronically actuated fuel control valve
- Gaseous fuel heater
- Electronically controlled gas shut-off valve
- Gas induction nozzles
- CSA certified gas electronic components
instrumentation
- Analog gauges
- EMCP 4.4 control panel
lube system
- Crankcase breather
- Oil cooler
- Oil filter
- Shallow oil pan
- Oil pan drain valve
mounting system
- Oilfield base
- Heavy-duty land rig inner baseframe — three-point mountto oilfield base
power take-offs
- Accessory drive
protection system
- ADEM A4 ECU monitoring system provides engine protectionstrategies to protect against adverse operating conditions.Selected parameters are customer programmable.
starting system
- Air starting motor
- Air silencer
general
- Paint — Cat yellow
- Vibration damper and guard
- Lifting eyes
- Lift and cable tow provisions
Optional Equipment
air inlet system
- Heavy-duty air cleaners and precleaners
- Remote air inlet adapters
charging system
- Battery charger
- Charging alternator
control system
- Load sharing module
- Cat digital voltage regulator
- Governor conversion
- 2301A load sharing governor
cooling systems
- High gloss black folded core radiators and conventional coreradiator
- Coolant regulator conversions
- Belt guard, radiator guard
- Blower fan – engine mounted
- Fan drive and fan pulley
- Radiator mounting
- Water level switch gauge
- Coolant level sensors
exhaust system
- Elbows
- Mufflers
- Flange and exhaust expanders
fuel system
- Primary fuel filter
- Fuel cooler
generator
- Oilfield spec twin-bearing, close-coupled
generator attachments
- Air filter
- Low voltage extension box
- Potential transformer
- Manual voltage control
- Current droop transformers
- Cable access box
- Bearing temperature detectors
instrumentation
- Customer programmable annunciator
- Gauges and instrument panels
- Switches, relays, and contractors
lube system
- Fumes disposal
- Oil filter, oil pan accessories
- Sump pumps
mounting system
- Oilfield outer base with three-point mount
power take-offs
- Front stub shaft
- Pulleys
protection system
- Explosion relieve valve, shutoffs
- Switches and contacts/relays
- Oil pressure monitors, sensors
starting system
- Air pressure regulator
- Starting aids
general
- Tool set
- Cat data link wire
Similar Products
C32 ACERT Tier 2 Oilfield Diesel Generator Set
Maximum Rating:
1600 ekW (2000 kVA)
Minimum Rating:
1600 ekW (2000 kVA)
Emissions/Fuel Strategy:
Non-certified
Aspiration:
Turbocharged-Aftercooled
CG137-12 Oilfield Gas Generator Set
Maximum Rating:
1600 ekW (2000 kVA)
Minimum Rating:
1600 ekW (2000 kVA)
Emissions/Fuel Strategy:
Non-certified
Aspiration:
Turbocharged-Aftercooled
C27 ACERT Tier 2 Oilfield Diesel Generator Set
Maximum Rating:
1600 ekW (2000 kVA)
Minimum Rating:
1600 ekW (2000 kVA)
Emissions/Fuel Strategy:
Non-certified
Aspiration:
Turbocharged-Aftercooled