At a glance data:
Frequency:
60 Hz
Natural Gas Rating:
200 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Engine Model:
14.2 L, Inline 6, 4 Cycle, Spark - Ignited
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Frequency:
60 Hz
Natural Gas Rating:
200 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Engine Specifications
Engine Model:
14.2 L, Inline 6, 4 Cycle, Spark - Ignited
Generator Set Specifications
Displacement:
864.71in
Engine Specifications
Fuel System:
Carburetor, Down Draft
Generator Set Specifications
Fuel Type:
Natural Gas
Speed:
1800 rpm
Engine Specifications
Aspiration:
Turbocharged-Aftercooled
Governor Type:
Electronic
Compression Ratio:
9.5:1
Bore:
5.31in
Stroke:
6.5in
Generator Set Dimensions
Length:
127.95in
Width:
52.93in
Height:
67.37in
Weight:
5756lb
Standard Equipment
cooling
- Closed coolant recovery system
- Factory-installed radiator
- 50/50 Ethylene glycol antifreeze
- Radiator and cooling fan complete with protective guards
- Standard ambient temperatures up to 50°C (122°F)
air inlet
- Single element air filter
fuel
- Primary and secondary fuel shut-off
- Low fuel pressure switch
- Fuel pressure test po
- Natural Gas or LP Vapor
- NPT connection
- Dual lock off valves
exhaust
- Exhaust outlet with 3” pipe
generator
- Permanent magnet excitation
- Full load capacity alternator
- Class H insulation material
- Permanent magnet excitation
- Integrated Voltage Regulator
- Matched to the performance and output characteristics of Cat engines
- Class H insulation material
- Full load capacity alternator
- IP23 Protection
controls
- EMCP 4.2 Series generator set controller
mounting
- Vibration isolaton (puck type)
- Rubber vibration isolators
electric power - package serial number prefix
- Battery charging alternator
electric starting and/or prelube
- Battery cables
- Solenoid activated starter motor
- Engine electrical system
- Solenoid activated starter motor
governor
- Electronic governor (non adjustable)
control panel
- EMCP 4.2 Series generator set controller
starting/charging
- Batteries with rack and cables
- 12 volt starting motor
Optional Equipment
starting/charging
- Jacket water heater
- Battery heater
- Charging alternator
- Battery charger – UL Listed 10 amp
general
- Enclosures: sound attenuated, weather protective
- Suitable for Use as Service Equipment (SUSE)
- Automatic transfer switches (ATS)
- UL 2200 package
- CSA Certification
generator
- Thermal magnetic or electronic trip MCCBs
- Anti-condensation heater
- Shunt trip and auxiliary contact breaker
- Anti-condensation heater
- Excitation: [ ] Permanent Magnet Excited (PM)
- Oversize and premium generators
Similar Products
G3516 1500kW Gas Generator Set
Frequency:
60 Hz
Natural Gas Rating:
200 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Engine Model:
14.2 L, Inline 6, 4 Cycle, Spark - Ignited
DG175-2 (3 phase)
Frequency:
60 Hz
Natural Gas Rating:
200 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Engine Model:
14.2 L, Inline 6, 4 Cycle, Spark - Ignited
G3412 Gas Generator Set
Frequency:
60 Hz
Natural Gas Rating:
200 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Engine Model:
14.2 L, Inline 6, 4 Cycle, Spark - Ignited