DG250-2 (3 phase)
- new - Products
- DG250-2 (3 phase)
At a glance data:
Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³
Engine Specifications
Fuel System:
Carbureter, Down Draft
Generator Set Specifications
Speed:
1800 rpm
Engine Specifications
Aspiration:
Turbocharged - Aftercooled
Compression Ratio:
9.5:1
Bore:
5.31in
Stroke:
6.5in
Generator Set Dimensions
Length:
138.74in
Width:
57.6in
Height:
68.04in
Weight:
6364lb
Standard Equipment
cooling
- Factory-installed radiator
- Closed coolant recovery system
- 50/50 Ethylene glycol antifreeze
- Standard ambient temperatures up to 50°C (122°F)
- Radiator and cooling fan complete with protective guards
air inlet
- Single element air filter
fuel
- Low fuel pressure switch
- Fuel pressure test po
- Primary and secondary fuel shut-off
- Dual lock off valves
- NPT connection
- Natural Gas or LP Vapor
generator
- Class H insulation material
- Full load capacity alternator
- Permanent magnet excitation
- Full load capacity alternator
- Permanent magnet excitation
- Matched to the performance and output characteristics of Cat engines
- Integrated Voltage Regulator
- Class H insulation material
- IP23 Protection
exhaust
- Exhaust outlet with 3” pipe
controls
- EMCP 4.2 Series generator set controller
mounting
- Vibration isolaton (puck type)
- Rubber vibration isolators
electric starting and/or prelube
- Solenoid activated starter motor
- Engine electrical system
- Battery cables
- Solenoid activated starter motor
electric power - package serial number prefix
- Battery charging alternator
governor
- Electronic governor (non adjustable)
control panel
- EMCP 4.2 Series generator set controller
starting/charging
- 12 volt starting motor
- Batteries with rack and cables
Optional Equipment
starting/charging
- Battery heater
- Battery charger – UL Listed 10 amp
- Jacket water heater
- Charging alternator
general
- CSA Certification
- Suitable for Use as Service Equipment (SUSE)
- UL 2200 package
- Enclosures: sound attenuated, weather protective
- Automatic transfer switches (ATS)
generator
- Shunt trip and auxiliary contact breaker
- Anti-condensation heater
- Thermal magnetic or electronic trip MCCBs
- Oversize and premium generators
- Excitation: [ ] Permanent Magnet Excited (PM)
- Anti-condensation heater
Similar Products
G3516 1500kW Gas Generator Set
Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³
DG175-2 (3 phase)
Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³
G3412 Gas Generator Set
Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³