Skip to content

DG250-2 (3 phase)

At a glance data:

Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³
enclosure

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Frequency:
60 Hz
Natural Gas Rating:
250 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Displacement:
864.7in³

Engine Specifications

Fuel System:
Carbureter, Down Draft

Generator Set Specifications

Speed:
1800 rpm

Engine Specifications

Aspiration:
Turbocharged - Aftercooled
Compression Ratio:
9.5:1
Bore:
5.31in
Stroke:
6.5in

Generator Set Dimensions

Length:
138.74in
Width:
57.6in
Height:
68.04in
Weight:
6364lb

Standard Equipment

cooling

  • Factory-installed radiator
  • Closed coolant recovery system
  • 50/50 Ethylene glycol antifreeze
  • Standard ambient temperatures up to 50°C (122°F)
  • Radiator and cooling fan complete with protective guards

air inlet

  • Single element air filter

fuel

  • Low fuel pressure switch
  • Fuel pressure test po
  • Primary and secondary fuel shut-off
  • Dual lock off valves
  • NPT connection
  • Natural Gas or LP Vapor

generator

  • Class H insulation material
  • Full load capacity alternator
  • Permanent magnet excitation
  • Full load capacity alternator
  • Permanent magnet excitation
  • Matched to the performance and output characteristics of Cat engines
  • Integrated Voltage Regulator
  • Class H insulation material
  • IP23 Protection

exhaust

  • Exhaust outlet with 3” pipe

controls

  • EMCP 4.2 Series generator set controller

mounting

  • Vibration isolaton (puck type)
  • Rubber vibration isolators

electric starting and/or prelube

  • Solenoid activated starter motor
  • Engine electrical system
  • Battery cables
  • Solenoid activated starter motor

electric power - package serial number prefix

  • Battery charging alternator

governor

  • Electronic governor (non adjustable)

control panel

  • EMCP 4.2 Series generator set controller

starting/charging

  • 12 volt starting motor
  • Batteries with rack and cables

Optional Equipment

starting/charging

  • Battery heater
  • Battery charger – UL Listed 10 amp
  • Jacket water heater
  • Charging alternator

general

  • CSA Certification
  • Suitable for Use as Service Equipment (SUSE)
  • UL 2200 package
  • Enclosures: sound attenuated, weather protective
  • Automatic transfer switches (ATS)

generator

  • Shunt trip and auxiliary contact breaker
  • Anti-condensation heater
  • Thermal magnetic or electronic trip MCCBs
  • Oversize and premium generators
  • Excitation: [ ] Permanent Magnet Excited (PM)
  • Anti-condensation heater