Skip to content

DG350-2 (Single-phase)

At a glance data:

Frequency:
60 Hz
Natural Gas Rating:
350 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application
Engine Model:
G21.9L Spark-Ignited
enclosure

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Frequency:
60 Hz
Natural Gas Rating:
350 eKW
Emissions/Fuel Strategy:
U.S. EPA Certified for Non-Emergency Application

Engine Specifications

Engine Model:
G21.9L Spark-Ignited

Generator Set Specifications

Fuel Type:
Natural Gas

Engine Specifications

Compression Ratio:
10.1
Fuel System:
Carburetor, Down Draft

Generator Set Specifications

Displacement:
1336.42in³

Engine Specifications

Governor Type:
Electronic

Generator Set Specifications

Speed:
1800 rpm

Engine Specifications

Aspiration:
Turbocharged - Aftercooled
Bore:
5.03in
Stroke:
5.6in

Generator Set Dimensions

Length:
154.4in
Width:
71in
Height:
67.6in
Weight:
8274lb

Standard Equipment

cooling

  • Closed coolant recovery system
  • 50/50 Ethylene glycol antifreeze
  • Factory-installed radiator
  • Radiator and cooling fan complete with protective guards
  • Standard ambient temperatures up to 50°C (122°F)

air inlet

  • Single element air filter

fuel

  • Primary and secondary fuel shut-off
  • Fuel pressure test po
  • Low fuel pressure switch
  • Dual lock off valves
  • NPT connection
  • Natural Gas or LP Vapor

exhaust

  • Exhaust outlet with 3” pipe

generator

  • Full load capacity alternator
  • Class H insulation material
  • Permanent magnet excitation
  • Permanent magnet excitation
  • Integrated Voltage Regulator
  • Class H insulation material
  • IP23 Protection
  • Matched to the performance and output characteristics of Cat engines
  • Full load capacity alternator

controls

  • EMCP 4.2 Series generator set controller

mounting

  • Vibration isolaton (puck type)
  • Rubber vibration isolators

electric starting and/or prelube

  • Engine electrical system
  • Battery cables
  • Solenoid activated starter motor
  • Solenoid activated starter motor

electric power - package serial number prefix

  • Battery charging alternator

governor

  • Electronic governor (non adjustable)

control panel

  • EMCP 4.2 Series generator set controller

starting/charging

  • 12 volt starting motor
  • Batteries with rack and cables

Optional Equipment

starting/charging

  • Charging alternator
  • Battery charger – UL Listed 10 amp
  • Battery heater
  • Jacket water heater

general

  • UL 2200 package
  • CSA Certification
  • Suitable for Use as Service Equipment (SUSE)
  • Automatic transfer switches (ATS)
  • Enclosures: sound attenuated, weather protective

generator

  • Anti-condensation heater
  • Thermal magnetic or electronic trip MCCBs
  • Shunt trip and auxiliary contact breaker
  • Excitation: [ ] Permanent Magnet Excited (PM)
  • Oversize and premium generators
  • Anti-condensation heater