3516E Low Voltage Generator Set
- new - Products
- 3516E Low Voltage Generator Set
At a glance data:
Standby Rating:
3000 kVA (3100 kVA without fan)
Prime Power Rating:
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Standby Rating:
3000 kVA (3100 kVA without fan)
Prime Power Rating:
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Standby, Mission Critical, Prime
Maximum Rating:
3000 kVA (3100 kVA without fan)
Minimum Rating:
2750 kVA (2850 kVA without fan)
Engine Specifications
Engine Model:
3516E, SCAC, V-16, 4-Stroke, Water-Cooled Diesel
Bore:
6.69in
Stroke:
8.46in
Displacement:
4766in
Compression Ratio:
14:01
Aspiration:
TA
Fuel System:
Electronic unit injection
Governor Type:
Adem™ A5
Generator Set Dimensions
Length - Maximum:
296.8in
Width - Maximum:
87.2in
Height - Maximum:
133.5in
Dry Weight - Genset (maximum):
43541lb
Standard Equipment
air inlet system
- Air cleaner
- Single element canister type with service indicator
control panel
- Environmental sealed front face
- Warning/shutdown with common LED indication of shutdowns for:
- Overspeed
- RPM
- Generator phase sequence
- Emergency stop pushbutton
- Digital indication for:
- Text alarm/event descriptions
- 2 Programmable digital outputs
- Reverse reactive power (kVAr) (32RV)
- Reverse power (kW) (32)
- Failure to start (overcrank)
- Panel lights
- Speed adjust
- Oil pressure (psi, kPa or bar)
- Low coolant level
- Generator mounted - rear facing
- Over/under frequency (81 o/u)
- Lamp test
- True RMS AC metering, 3-phase, +/-2% accuracy
- Low coolant temperature
- Power factor (per phase & average)
- Frequency (Hz)
- Overcurrent (50/51)
- High coolant temperature
- DC volts
- 6 Programmable digital inputs
- Coolant temperature
- 24 Volt DC operation
- Amps (per phase & average)
- Emergency stop
- Alarm acknowledge
- Programmable protective relaying functions:
- 2 Programmable relay outputs (Form C)
- EMCP 4.2B
- Serial annunciator module data link
- Controls:
- kW-hr (total)
- kW (per phase, average & percent)
- Engine cool-down timer
- Operating hours
- EMCP 4 Genset controller
- Volts (L-L & L-N)
- Engine cycle crank
- Communications:
- kVAr (per phase, average & percent)
- EMCP4.2B controller includes:
- Customer data link (Modbus RTU)
- Over/under voltage (27/59)
- Low oil pressure
- kVA (per phase, average & percent)
- kVAr-hr (total)
- 4 Programmable relay outputs (Form A)
- Accessory module data link
exhaust
- Exhaust flange outlet
fuel
- Primary fuel filter with integral water separator
generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
power termination
- Busbar
starting/charging
- Heavy duty starting system
- Charging alternator
cooling system
- Caterpillar extended life coolant
- Radiator fan and fan drive
- Fan and belt guards
- JWAC
- Coolant drain line with valve
- Coolant level sensors
cooling
- Package mounted radiator
exhaust system
- Dry exhaust manifold
- Flanged faced outlet(s)
fuel system
- Secondary fuel filters
- Fuel priming pump
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
generators and attachments
- Internal excitation (IE)
- 6 Lead
- Busbar connections, top center mounted, top cable entry
- IEC standard hole pattern
- Random wound
- 3 Phase brushless, Salient pole
- Winding temperature detectors
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby).
- Generator set packages include Caterpillar's digital voltage regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
governing system
- ADEM III
literature
- Parts book
lube system
- Lubricating oil
- Oil filter, filler and dipstick
- Fumes disposal
- Oil drain lines and valve
- Gear type lube oil pump
- Integral lube Oil cooler
mounting system
- Rubber anti-vibration mounts - shipped loose
- Rails - Engine/generator/radiator mounting
starting / charging system
- Battery and battery rack w/cables
- 24 Volt electric starting motor
- Battery disconnect switch
general
- Right hand servicing
- Paint - Caterpillar yellow with high gloss black rails & radiator
- Flywheel and flywheel housing-SAE No. 00
- SAE standard rotation
Optional Equipment
air inlet system
- Air inlet protection
- Heavy duty air cleaners
- Remote air inlet adapters
- Dual element air cleaners
circuit breakers
- Cable entry options
- Control packaging for enclosures
- Optional busbar power connections
- EMAX breakers
- Load take off; IEC standard hole
- Center posts busbars
- Trip units
power termination
- Circuit breakers, IEC compliant
control panels
- External box clips
- Local and remote monitoring
- Busbar connections
- Governors
- Generator temperature monitoring
- Auxiliary box
- Voltage raise/lower switch
- EMCP 4.3, EMCP 4.4
- EMAX breaker connections
- Language options
- Remote speed adjust
- Annunciator modules
- Customer interface options
- Vandal proof panel door
cooling system
- Optional Serpentine radiators
- Water level switch gauges
- Heat exchangers
- Radiator duct flanges
european certifications
- EU Declaration of Conformity
exhaust system
- Mufflers
- Through wall installation kit
- Flexible fittings
- Muffler mounting kits
fuel system
- Fuel coolers
- Primary fuel filter
generators and attachments
- 3 Phase, Random wound, Internal excitation (IE)
- Internal excitation (IE)
- Random wound
- Pitch: 0.6667
- Optional generators
- Number of leads: 6
- 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt
instrumentation
- Thermocouples
- Pyrometers and thermocouples
lube system
- Manual prelube sump pumps
- Oil level regulator
- Electric prelube pumps
mounting system
- Spring type vibration isolators
- IBC vibration isolators
protection system
- Explosion relief valves
special tests / reports
- PGS Test report @ 0.8 power factor
- CSA test and certification
- Neutral ground certificate
- PGS Test report @ 1.0 power factor
- IBC seismic Certification
starting / charging system
- Jacket water heaters
- ETHER starting aids
- Dual 24 volt electric starting motors
- 24 Volt battery set - Dry
- Charging alternators - 50 Amp
- 10 and 20 Amp Battery chargers
general
- Engine barring group
Cat Switchgear
Standby Rating:
3000 kVA (3100 kVA without fan)
Prime Power Rating:
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Standby Rating:
3000 kVA (3100 kVA without fan)
Prime Power Rating:
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 volts
C9 Generator Set
Standby Rating:
3000 kVA (3100 kVA without fan)
Prime Power Rating:
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 volts
DE165E0 (50 Hz) Generator Set
Standby Rating:
3000 kVA (3100 kVA without fan)
Prime Power Rating:
2750 kVA (2850 kVA without fan)
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 volts