Cat Switchgear
- new - Products
- Cat Switchgear
At a glance data:
Configuration:
IP4X
Operating Temperature:
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths:
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary:
Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Overview
Cat Paralleling Switchgear is the perfect complement for the control and distribution of your emergency power. Modular and Customizable, it can be designed with protection and control architecture.
Enclosure Rating
Configuration:
IP4X
Operating Temperature
Operating Temperature:
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Dimensions
Standard Widths:
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary
Technical Summary:
Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Application
Application:
LV 380…480 VAC, 50 Hz, 3-Phase.
Modes of Operation
Modes of Operation:
Switchgear integration options for multi generator and utility synchronising, load sharing, Peak Lopping/Shaving, AMF, Changeover, Load bank connection, Protection relay etc.
Dimensions
Standard Heights:
Heights include 100mm plinth with fork lift pockets, 1900 mm up to 3200A, 2200 mm for 400,2200 mm for PLC and control cabinets. Option for single point lifting on 4 corners with M10 swivel eyes. Standard sizes for shipping
Standard Depths:
300, 450 & 750mm for controls and PLC cabinets. 900mm for fixed breakers. 1050mm for withdrawable breakers
Standard Equipment
Optional Equipment
Similar Products
Engine Paralleling and Integration Control (EPIC)
Configuration:
IP4X
Operating Temperature:
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths:
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary:
Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Cat Switchgear
Configuration:
IP4X
Operating Temperature:
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths:
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary:
Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.
Cat XLM Switchgear
Configuration:
IP4X
Operating Temperature:
35 °C / 40 °C @ 1 hr, option for 0…50 °C (32…122 °F)
Standard Widths:
600 mm for ABB Emax2 E2 1600 - 2500A. 750 mm for ABB Emax2 E4 3200 - 4000A. 1200 mm for ABB Emax2 E6 4000 - 6300A.
Technical Summary:
Modular system enables any configuration Distribution Boards, Motor Control Centers & PLC Control cabinets. Accommodates fixed or withdrawable breakers.