3512 Generator Set
- new - Products
- 3512 Generator Set
At a glance data:
Standby Rating:
1250/1100 ekW
Prime Power Rating:
1135/1000 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 13800 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Standby Rating:
1250/1100 ekW
Prime Power Rating:
1135/1000 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 13800 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Mission Critical, Prime, Continuous
Maximum Rating:
1250 ekW
Minimum Rating:
890 ekW
Engine Specifications
Engine Model:
3512 TA, V-12, 4-Stroke Water-Cooled Diesel
Bore:
6.69in
Stroke:
7.48in
Displacement:
3161.03in³
Compression Ratio:
13.5:1
Aspiration:
TA
Fuel System:
Direct Unit Injection
Governor Type:
Woodward
Generator Set Dimensions
Length - Minimum:
214.8in
Length - Maximum:
218.8in
Width - Maximum:
77.8in
Height - Maximum:
93.2in
Dry Weight - Genset (minimum):
22210lb
Dry Weight - Genset (maximum):
22650lb
Standard Equipment
air inlet system
- Air cleaner; single element canister type with service indicator
air inlet
- Air cleaner
cooling
- Radiator fan and fan drive
- JWAC.
exhaust
- Exhaust flange outlet
- Dry exhaust manifold
fuel
- Secondary fuel filters
- Primary fuel filter with integral water separator
- Fuel cooler; not included with packages without radiator
- Secondary fuel filters
- Fuel priming pump
generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
power termination
- Busbar
control panel
- Accessory module data link
- Features include:
- Over/under voltage (27 / 59)
- Coolant temperature
- Generator phase sequence
- Serial annunciator module data link
- Low coolant temperature
- Low oil pressure
- DC volts
- Over/under voltage (27/59)
- Auto/start/stop control
- Exciter diode monitor
- Failure to start (overcrank)
- 6 programmable digital inputs
- Emergency stop
- Generator mounted - rear facing
- Programmable protective relaying functions:
- Power factor (per phase & average)
- Alarm acknowledge
- DC volts
- kVA (per phase, average & percent)
- Overspeed
- IVR includes:
- RFI suppression
- Emergency stop pushbutton
- Package mounted radiator (except C175)
- Overspeed
- Emergency stop
- kVAr (per phase, average & percent)
- Environmental sealed front face
- Customer data link (Modbus RTU)
- Min / max exciter limiter
- Speed adjust
- Operating hours
- True RMS AC metering, 3-phase, +/-2% accuracy
- Reactive droop capability
- Customizable screens
- Volts (L-L & L-N)
- PLC functionality
- Digital indication for:
- RPM
- High coolant temperature
- Digital indication for:
- kW-hr (total)
- Over/under frequency (81 o / u)
- Low coolant temperature
- 24 Volt DC operation
- kW-hr (total)
- Oil pressure (psi, kPa or bar)
- Warning/shutdown with common LED indication of shutdowns for:
- kVAr-hr (total)
- EMCP 4.2B
- 2 Programmable relay outputs (Form C)
- kVAr-hr (total)
- kW (per phase, average & percent)
- kVAr (per phase, average & percent)
- Engine cool-down timer
- Over/under frequency (81 o/u)
- Engine cool-down timer
- True RMS AC metering, 3-phase, +/-2% accuracy
- Low coolant level
- Frequency (Hz)
- Controls:
- Generator phase sequence
- High coolant temperature
- Communications:
- Reverse power (kW) (32)
- Volts (L-L & L-N), frequency (Hz)
- Alarm acknowledge
- Environmental sealed front face
- Controls:
- Operating hours
- Generator mounted - rear facing
- Power factor (per phase & average)
- kW (per phase, average & percent)
- Programmable protective relaying functions:
- Engine cycle crank
- Reverse power (kW) (32)
- 24 Volt DC operation
- Lamp test
- Text alarm/event descriptions
- Failure to start (overcrank)
- Generator set packages include Caterpillar's voltage regulator (IVR)
- Warning/shutdown with common LED indication of shutdowns for:
- Text alarm/event descriptions
- 4 programmable relay outputs (Form A)
- Lamp test
- Load histogram feature
- Coolant temperature
- Auto/start/stop control
- Overcurrent (50 / 51)
- kVA (per phase, average & percent)
- KVAR/PF modes
- Engine cycle crank
- 3 Phase voltage sensing
- 2 Programmable digital outputs
- Low oil pressure
- Reverse reactive power (kVAr) (32RV)
- EMCP 4 Genset controller
- RPM
- Oil pressure (psi, kPa or bar)
- Amps (per phase & average)
- Low coolant level
- Amps (per phase & average)
- EMCP4.2 controller includes:
cooling system
- Radiator fan and fan drive
- Fan and belt guards
- JWAC
- Caterpillar extended life coolant
- Coolant level sensors
- Coolant drain line with valve
exhaust system
- Dry exhaust manifold.
- Exhaust flange outlet
fuel system
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
- Secondary fuel filters
- Fuel priming pump
generators and attachments
- LV
- Winding temperature detectors
- 3 phase brushless, Salient pole
- 1800 Frames are Form wound, Permanent magnet excitation (PMG), with winding temperature detectors
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Generator set packages include Caterpillar's digital voltage regulator (CDVR)
- CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
- 6 Lead
- Internal excitation (IE)
- Busbar connections, top center mounted, top cable entry. 50 Hz models: IEC standard hole pattern
- Random wound
governing system
- Woodward 2301A isochronous governor
lube system
- Integral lube Oil cooler
- Oil filter, filler and dipstick
- Oil drain lines and valve
- Fumes disposal
- Gear type lube oil pump.
- Lubricating oil
mounting system
- Rubber anti-vibration mounts - shipped loose
- Rails - engine/generator/radiator mounting
starting / charging system
- Battery disconnect switch
- Battery and battery rack w/cables
- 24 Volt electric starting motor
generator and attachments
- Random wound
- LV
- 6 Lead
- 3 phase brushless, Salient pole
general
- Right hand servicing
- Caterpillar yellow with high gloss black rails & radiator
- Flywheel and Flywheel housing-SAE No. 00
- SAE standard rotation
- Paint - Caterpillar yellow except rails and radiators gloss black
Optional Equipment
exhaust
- Exhaust mufflers
air inlet system
- Air inlet protection
- Air cleaner - Dual element
- Remote air inlet adapters
generator
- Oversize and premium generators
- Internal excitation (IE)
- Permanent magnet excitation (PMG)
- Anti-condensation heater
circuit breakers
- Breaker harnesses
- EMAX breaker connections
- EMAX breakers
- Enclosures - Control packaging
- Cable entry options
- Low voltage, IEC standard hole
- Optional busbar power connections
- Busbar connections
power termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
control panels
- Annunciator modules
- Customer interface options
- Auxiliary box
- Mounting group - External box clips
- Governors
- Generator temperature monitoring
cooling system
- Heat exchangers
- 3512 MUI 1500 Radiators PGS
- Water level switch gauges
mounting
- Spring type vibration isolators
- IBC isolators
- Rubber anti-vibration mounts
certificates
- EU Declaration of Conformity
- Eurasian Conformity (EAC) mark
- European union certification
- European Directive genset, DoI (Declaration of Incorporation)
starting/charging
- Jacket water heater
- Battery chargers
- Charging alternator
- Heavy duty starting system
- Oversize batteries
- Air starting motor with control and silencer
exhaust system
- Flexible fittings
- Mufflers
- Through wall installation kit
fuel system
- Primary fuel filter
generators and attachments
- Space heater kit
- Generator conversions - IE and PM
instrumentation
- Pyrometers
lube system
- Oil level reg-1 shallow pan
- Manual prelube sump pumps
- Electric prelube pumps
mounting system
- Vibration isolator options
protection system
- Explosion relief valves
special tests / reports
- PGS Test report @ 0.8 power factor
- Neutral ground - LV
- PGS Test report @ 1.0 power factor
- IBC seismic Certification
- Neutral grounding connection
starting / charging system
- Battery chargers (10 and 20 amp)
- Battery sets - 24 Volt, dry
- Electric starting motors - Dual 24 Volt
- Charging alternators
- Jacket water heaters
- Starting aids
general
- Integral & sub-base fuel tanks
- Enclosures: Sound attenuated, weather protective
- Engine barring group - installed
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- CSA Certification
- Integral & sub-base UL listed dual wall fuel tanks
- The following options are based on regional and product configuration:
- Automatic transfer switches (ATS)
- UL 2200 package
- EU Certificate of Conformance (CE)
- EEC Declaration of Conformity
Cat Switchgear
Standby Rating:
1250/1100 ekW
Prime Power Rating:
1135/1000 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 13800 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Standby Rating:
1250/1100 ekW
Prime Power Rating:
1135/1000 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 13800 Volts
C9 Generator Set
Standby Rating:
1250/1100 ekW
Prime Power Rating:
1135/1000 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 13800 Volts
DE165E0 (50 Hz) Generator Set
Standby Rating:
1250/1100 ekW
Prime Power Rating:
1135/1000 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 13800 Volts