3516B Generator Set
- new - Products
- 3516B Generator Set
At a glance data:
Standby Rating:
2250 ekW
Prime Power Rating:
1825 ekW
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 13800 Volts
Print
Electric Power Ratings Guide
3516B, 60 Hz, 2250 ekW Standby/MC, Low Fuel Consumption Spec Sheet
3516B, 60 Hz, 2000 ekW Standby/MC, 1825 ekW Prime, 1640 ekW Cont., Low Fuel Consumption and Low Emissions Spec Sheet
3516B, 60 Hz, 1825 ekW, Prime-DCP, Low Fuel Consumption or Low Emissions Spec Sheet
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Standby Rating:
2250 ekW
Prime Power Rating:
1825 ekW
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 13800 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Mission Critical, Prime, Continuous
Maximum Rating:
2250 ekW
Minimum Rating:
1640 ekW
Engine Specifications
Engine Model:
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore:
6.69in
Stroke:
7.48in
Displacement:
4210.64in³
Compression Ratio:
14.0:1 Std 15.5:1 HD
Aspiration:
TA
Fuel System:
Electronic unit injection
Governor Type:
Adem™3
Generator Set Dimensions
Length - Maximum:
251.4in
Width - Maximum:
90in
Height - Maximum:
98.2in
Dry Weight - Genset (maximum):
31270lb
Standard Equipment
air inlet system
- Air cleaner; single element canister type
cooling
- Package mounted radiator
exhaust
- Exhaust flange outlet
fuel
- Primary fuel filter with integral water separator
- Secondary fuel filters
- Fuel priming pump
generator
- IP23 Protection
- Matched to the performance and output characteristics of Cat engines
power termination
- Busbar
control panel
- Cat ECS Genset controller
general
- Paint - Caterpillar yellow except rails and radiators gloss black
control panels
- Speed adjust
- Text alarm/event descriptions
- Generator set packages include Caterpillar's voltage regulator
- Auto/start/stop control
- 24 Volt DC operation
- Cat ECS 100
- Generator mounted - Rear facing
- Controls:
- Environmental sealed front face
- Engine cool-down timer
- Emergency stop pushbutton
- Limiter and exciter diode monitor
- Engine cycle crank
- Lamp test
- Alarm acknowledge
- Customizable screens
- PLC functionality
- Load histogram feature
- 0 True RMS AC metering, 3-phase, +/-2% accuracy
- Operating hours
- Digital indication for:
- DC volts
- RPM
- Coolant temperature
- Amps (per phase & average)
- Oil pressure (psi, kPa or bar)
- Volts (L-L & L-N)
- Frequency (Hz)
- Power factor (per phase & average)
- kW (per phase, average & percent)
- High coolant temperature
- Low oil pressure
- Warning/shutdown with common LED indication of shutdowns for01/10/2018:
- kVAr (per phase, average & percent)
- kVA (per phase, average & percent)
- kVAr (per phase, average & percent)
- Emergency stop
- Overspeed
- Failure to start (overcrank)
- Programmable protective relaying functions:
- Low coolant temperature
- Generator phase sequence
- Low coolant level
- 1 Programmable digital outputs
- Gear type lube oil pump
- Battery disconnect switch
- Caterpillar yellow with high gloss black rails and radiator
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Medium voltage: Form wound - Permanent magnet excitation (PMG) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - Busbar connections, right side extension box, bottom cable entry - NEMA standard hole pattern
- Fumes disposal
- Permanent magnet excitation (PMG)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Permanent magnet excitation (PMG)
- NEMA standard hole pattern
- Reverse reactive power (kVAr) (32RV)
- Over/under voltage (27/59)
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Permanent magnet excitation (PMG)
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- Permanent magnet excitation (PMG)
- SAE standard rotation
- Internal excitation (IE)
- Flexible fuel lines - shipped loose
- IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min / max exciter
- Busbar connections, right side extension box, bottom cable entry
- Medium voltage:
- Communications:
- NEMA standard hole pattern
- Lubricating oil
- Oil drain lines and valve
- 3 Phase brushless, Salient pole
- 24 Volt electric starting motor
- 6 Customer programmable digital inputs
- Dry exhaust manifold
- Accessory module data link
- ADEM A3
- Form wound
- ATAAC - 3516E package radiators shipped installed
- Busbar connections, top center mounted, top cable entry
- High voltage:
- 4 Programmable relay outputs (Form A)
- Anti-condensation space heater
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Controls: Speed adjust - Auto/start/stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy
- NEMA standard hole pattern
- 45 Amp Charging alternator
- 3 Analog inputs
- Random wound
- Anti-vibration mounts (shipped loose)
- Cat connect
- Oil filter, filler and dipstick
- Rails - Engine/generator/radiator mounting
- Customer data link (Modbus RTU)
- Flywheel and flywheel housing - SAE No. 00
- English
- Busbar connections, right side extension box, bottom cable entry
- Serial annunciator module data link
- Integral lube oil cool
- Certified standard PGS provided
- Winding temperature detectors
- 1 Programmable relay outputs (Form C)
- Reverse power (kW) (32)
- Form wound - Permanent magnet excitation (PMG)
- Right hand servicing
- Overcurrent (50/51)
- 6 Lead
- Flanged faced outlet(s)
- Low voltage:
- Number of I/O varies on options selected
- Battery and battery rack w/cables
- Over/under frequency (81 o/u)
- Fuel cooler; not included with packages without radiator
- Busbar connections, right side extension box, bottom cable entry
- Rubber anti-vibration mounts - shipped loose
- NEMA standard hole pattern
Optional Equipment
control system
- EMCP 4.4
air inlet system
- Single element filter
- Dual element air cleaner
exhaust
- Exhaust mufflers
generator
- Permanent magnet excitation (PMG)
- Internal excitation (IE)
- Anti-condensation heater
- Oversize and premium generators
cooling system
- Water level switch gauges
- Standard ambient radiators
- Coolant
- Standard ambient ATAAC radiators
- Optional installed ATAAC radiators
- Air inlet protection including air shut off magnetic switch
- Optional installed radiator
power termination
- Circuit breakers, IEC compliant
- Circuit breakers, UL listed
control panels
- Generator temperature monitoring & protection
- Remote monitoring software
- Load share module
- Digital I/O module
exhaust system
- Exhaust Offset
- Flanges
- Elbows
- Y Adapters
- Flange and exhaust expanders
- Clean emission parets
- Mufflers
- Flexible fittings
fuel system
- Primary fuel filter
general
- Special paint
- US aid emblem
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- EEC Declaration of Conformity
- Integral & sub-base fuel tanks
- Enclosures: Sound attenuated, weather protective
- Integral & sub-base UL listed dual wall fuel tanks
- EU Certificate of Conformance (CE)
- The following options are based on regional and product configuration:
- Automatic transfer switches (ATS)
- UL 2200 package
mounting
- Rubber anti-vibration mounts
- Spring type vibration isolators
- IBC isolators
generators and attachments
- Generator conversions - IE and PM
- 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 Frame
- 380, 440, 480, 600 Volts, 3 phase, 1800 rpm, RW, IE, No. of leads: 6, Picth: 0.6667 - 1600 Frame
- 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 phase, 1800 rpm, RW, PM, No. of leads: 6, Picth: 0.6667 - 1600 and 1800 Frames
- Alternator air cleaner
- Space heater
intrumentation
- Pyrometer and thermocouples
lube system
- Prelube pump groups
- Oil lever regulator
- Lube oil
starting/charging
- Battery chargers
- Air starting motor with control and silencer
- Heavy duty starting system
- Oversize batteries
- Charging alternator
crankcase systems
- Crankcase protection group: No explosion relief valves; Explosion relief valves
- Crankcase ventilation system
mounting system
- Spring type vibration isolators
- IBC vibration isolators
- Puck style low efficiency isolators
power connections
- Neutral ground connections
- Center post busbarss
- Right, left side and rear power connections
- Grounding groups
special tests / reports
- Standard engine test charge
- IBC Certification
- Special package tests: PGS Test report @ 1.0 and 0.8 power factors
- Generator set test report
- CSA Certification
- Torsional vibration analysis TVA report
- Fuel consumption test
starting / charging sytem
- Jacket water heaters
Cat Switchgear
Standby Rating:
2250 ekW
Prime Power Rating:
1825 ekW
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 13800 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Standby Rating:
2250 ekW
Prime Power Rating:
1825 ekW
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 13800 Volts
C9 Generator Set
Standby Rating:
2250 ekW
Prime Power Rating:
1825 ekW
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 13800 Volts
DE165E0 (50 Hz) Generator Set
Standby Rating:
2250 ekW
Prime Power Rating:
1825 ekW
Emissions/Fuel Strategy:
Low Fuel, Low Emissions
Voltage:
380 to 13800 Volts