3412C Generator Set

At a glance data:

Maximum Rating:
800 ekW
Minimum Rating:
635 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
220 to 480 Volts

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Maximum Rating:
800 ekW
Minimum Rating:
635 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
220 to 480 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Prime

Engine Specifications

Engine Model:
3412C TA, V-12, 4-Stroke Water-Cooled Diesel
Bore:
5.4in
Stroke:
6in
Displacement:
1648.86in³
Compression Ratio:
13:00:01
Aspiration:
TA
Fuel System:
Pump and Lines
Governor Type:
ADEM™ A5

Generator Set Dimensions

Length - Maximum:
162.4in
Width - Maximum:
78.3in
Height - Maximum:
75in
Dry Weight - Genset (minimum):
5761lb
Dry Weight - Genset (maximum):
13275lb

Standard Equipment

air inlet system

  • Air cleaner, single element canister type
  • Single element canister type

control panel

  • High coolant temperature
  • Customer data link (Modbus RTU)
  • Low coolant temperature
  • Low coolant level
  • Communications:
  • Run/auto/ stop/control
  • Engine cycle crank
  • Generator temperature monitoring module
  • Power factor (per phase & average)
  • Remote CAN annunciator
  • Serial annunciator module data link
  • DC volts
  • Frequency (Hz)
  • Operating hours.
  • Emergency stop pushbutton
  • Digital I/O module
  • Local annunciator
  • Low oil pressure
  • Oil pressure (psi, kPa or bar)
  • Emergency stop
  • Warning shutdowns:
  • Volts (L-L & L-N)
  • Remote Serial annunciator
  • Speed adjust
  • Amps (per phase & average)
  • Voltage adjust
  • EMCP 4.2B
  • Overspeed
  • coolant temperature
  • Digital Indicator for:
  • RPM
  • Accessory module data link
  • Failure to start (overcrank)
  • Controls:
  • Compatible with the following optional modules:

cooling system

  • Caterpillar extended life coolant
  • Radiator with guard (sized for 50 degrees C)
  • Fan and belt guards
  • Coolant drain line with valve

exhaust system

  • Stainless steel exhaust flex with ANSI style outlet flange

fuel system

  • Primary and Secondary fuel filters
  • Fuel priming pump
  • Water separator

generator and attachments

  • 3 Phase sensing
  • SR4B self excited
  • Class F temperature rise
  • VR6B voltage regulator
  • Busbar termination
  • 12 Leads
  • Class H insulation
  • 2:1 Volts/Hz
  • Reactive droop

governing system

  • Cat electronic governor

lube system

  • Oil drain line with valve
  • Lubricating oil
  • Oil filter

mounting system

  • Base, formed steel with linear vibration isolators between base and engine-generator

starting / charging system

  • Battery with rack, cables
  • 45 Amp Charging alternator
  • Fuel shutoff solenoid
  • 24 Volt starting motor

general

  • Paint - Caterpillar yellow except rails and radiators gloss black

Optional Equipment

air inlet system

  • Air cleaner - Dual element
  • Air cleaner - Heavy element
  • Air cleaner - single element

certificates

  • EU Certification

circuit breakers

  • 4 Pole Circuit breakerswith shunt trip
  • 3 Pole Circuit breakers with shunt trip
  • Power terminal strip

control panel

  • EMCP 4.3, EMCP 4.4
  • Temperature monitoring package
  • Vandal proof panel door
  • Generator running VFC
  • Earth leakage Ground fault relay
  • Common alarm/shutdown relay

cooling system

  • Jacket water heater
  • Radiator duct flange
  • Radiator removal

exhaust system

  • Muffler 10 dBA attenuation
  • Manifold and turbocharger guards
  • Muffler 35 dBA attenuation
  • Elbow mounting kit
  • Through wall installation kit

fuel system

  • Manual fuel transfer pump
  • Automatic fuel transfer system

generator and attachments

  • Internal excitation (IE)
  • Anti-condensation heater
  • Permanent magnet excitation (PMG)
  • Oversize and premium generators

governing system

  • Electronic load share

lube system

  • Manual sump pump

mounting system

  • Fuel tank base (1200 Ltr)

special tests / reports

  • PGS Test report @ 1.0 power factor
  • PGS Test report @ 0.8 power factor
  • Factory witness test

starting / charging system

  • Oversize battery set
  • Battery chargers
  • Heavy duty starting system
  • Battery disconnect switch
  • Battery removal

enclosures

  • DC lighting package
  • Weather protective enclosure (WP)
  • Sound attenuated enclosure (SA)
Cat Switchgear

Cat Switchgear

Maximum Rating:
800 ekW
Minimum Rating:
635 ekW
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
220 to 480 Volts