Cat C32 Generator Set (US EPA Tier 3 / IMO II)
- new - Products
- Cat C32 Generator Set (US EPA Tier 3 / IMO II)
At a glance data:
Minimum Rating:
219 ekW
Maximum Rating:
940 ekW
Frequency:
60hz
Rated Engine Speed:
1800 rpm
Overview
Generator Set Specifications
Minimum Rating:
219 ekW
Maximum Rating:
940 ekW
Frequency:
60hz
Engine Specifications
Rated Engine Speed:
1800 rpm
Configuration:
Vee-12, 4-stroke-Cycle-Diesel
Aspiration:
Turbocharged-aftercooled aspiration
Bore:
5.71in
Stroke:
6.38in
Displacement:
1959in³
Governor:
Electronic (A4 ECM)
Emissions:
U.S. EPA Tier 3 / IMO II emissions certified
Generator Set Dimensions
Length:
167.2 in/4245 mm (minimum), 226.1 in/5742 mm (maximum)
Width:
59.9 in/1521 mm (minimum), 89.8 in/2280 mm (maximum)
Height:
70.4 in/1747 mm (minimum), 92.8 in/2356 mm (maximum)
Package Dry Weight:
15721 lb/7131 kg (minimum), 21998 lb/9978 kg (maximum)
Engine Specifications
Generator:
SR5 - Form Wound
Refill Capacity:
Lube Oil System w/ oil filter change: 146 L (38.5 gal)
Cooling:
Heat exchanger, keel or radiator cooled
Oil Change Interval:
750 hrs
Standard Equipment
air inlet system
- Separate circuit aftercooled (SCAC)
control system
- 24V control system
cooling system
- Heat exchanger, keel or radiator cooled
- Watercooled exhaust manifold and turbocharger
- Hard seawater lines – no flexible hoses
- Flanges for cooling connections, ANSI or DIN
fuel system
- Duplex fuel filters with hybrid fuel lines
- Fuel transfer and priming pump
generators and generator attachments
- IP23, air cooled, form wound SR5 generator offered in 440, 480 and 690V
lube system
- Oil fill, simplex filter and dipstick
mounting system
- Helical spring/rubber isolated mounting for vibration and structure borne noise reduction
general
- Right or left hand service sides
- Customer wiring and service tool connector
Optional Equipment
air inlet system
- Closed crankcase ventilation
alarm and protection
- MGCP II or MGCP IIIB control panel with Cat® alarm and protection system
- IP44 generator protection
exhaust system
- Muffler
- SOLAS approved spray shielding
charging system
- Charging alternator
control system
- EMCP 4.2 control panel
fuel system
- Installed primary fuel filter with water separator and manual or electric priming pump
- Fuel cooler
lube system
- Duplex oil filters
starting system
- Starting motors – air, electric or dual
Similar Products
Cat C32 ACERT Generator Set (IMO II)
Minimum Rating:
219 ekW
Maximum Rating:
940 ekW
Frequency:
60hz
Rated Engine Speed:
1800 rpm
C1.5 Marine Generator Set Engine
Minimum Rating:
219 ekW
Maximum Rating:
940 ekW
Frequency:
60hz
Rated Engine Speed:
1800 rpm
Cat C280-12 Marine Generator Set
Minimum Rating:
219 ekW
Maximum Rating:
940 ekW
Frequency:
60hz
Rated Engine Speed:
1800 rpm