Cat® CBS – ATS with Bypass Isolation (Spec Grade)
- new - Products
- Cat® CBS – ATS with Bypass Isolation (Spec Grade)
At a glance data:
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Overview
The CBS Series – Open Transition, Delayed Transition (CBSD), Closed Transition (CBSCT), ATS with Bypass Isolationis is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.
The CBS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health. Fast switching and no line voltages connected at the door provide advanced safety.
Technical Summary
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
System Information
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Rated Voltage and Frequency:
200-480VAC, 50/60 Hz
Phase system:
Single and Three
Number of poles:
2, 3 and 4
Neutral configuration:
Solid neutral, Switched neutral, Overlapping neutral (100-1200A only)
Product type:
Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II)
Standard Equipment
control
- Color touchscreen
- Voltage and frequency settings: Pick up and Drop out
- Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
- Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
additional features
- LED indications for ATS, S1 and S2 status
- Programmable digital inputs/outputs
- Auto config (voltage, frequency, phase system)
- Source priority (Source 1/2, No priority)
- Manual re-transfer
- In-phase monitor (synchro check)
- Genset exercising: on-load, off-load
- In-built power meter module
- Load shedding
- Real time clock
- Event log
- Predictive maintenance
- Voltage and current harmonics measuring
accessories
- Auxiliary contacts for position indication
- Digital input/output modules (factory programmed)
- 12-24 VDC aux supply module for controller
- Communication modules
connectivity capability
- Modbus RTU (RS-485)
- Modbus/TCP
- Profibus DP
- ProfiNet Yes
- DeviceNet
- Ethernet IP
applications
- Utility - Utility
- Utility - Generator
ul short circuit withstand ratings
- Coordinated breaker WCR
- Time-based WCR
- Short-time ratings
Optional Equipment
options
- Options not available
Cat® CG – ATS for general purpose applications
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Cat® CS – ATS (Spec Grade)
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Similar Products
Cat® CS – ATS (Spec Grade)
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Cat® CG – ATS for general purpose applications
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Cat® CBS – ATS with Bypass Isolation (Spec Grade)
Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A