Cat® CBS – ATS with Bypass Isolation (Spec Grade)

At a glance data:

Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A

Overview

The CBS Series – Open Transition, Delayed Transition (CBSD), Closed Transition (CBSCT), ATS with Bypass Isolationis is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.

The CBS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health. Fast switching and no line voltages connected at the door provide advanced safety.

Technical Summary

Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor

System Information

Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
Rated Voltage and Frequency:
200-480VAC, 50/60 Hz
Phase system:
Single and Three
Number of poles:
2, 3 and 4
Neutral configuration:
Solid neutral, Switched neutral, Overlapping neutral (100-1200A only)
Product type:
Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II)

Standard Equipment

control

  • Color touchscreen
  • Voltage and frequency settings: Pick up and Drop out
  • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
  • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence

additional features

  • LED indications for ATS, S1 and S2 status
  • Programmable digital inputs/outputs
  • Auto config (voltage, frequency, phase system)
  • Source priority (Source 1/2, No priority)
  • Manual re-transfer
  • In-phase monitor (synchro check)
  • Genset exercising: on-load, off-load
  • In-built power meter module
  • Load shedding
  • Real time clock
  • Event log
  • Predictive maintenance
  • Voltage and current harmonics measuring

accessories

  • Auxiliary contacts for position indication
  • Digital input/output modules (factory programmed)
  • 12-24 VDC aux supply module for controller
  • Communication modules

connectivity capability

  • Modbus RTU (RS-485)
  • Modbus/TCP
  • Profibus DP
  • ProfiNet Yes
  • DeviceNet
  • Ethernet IP

applications

  • Utility - Utility
  • Utility - Generator

ul short circuit withstand ratings

  • Coordinated breaker WCR
  • Time-based WCR
  • Short-time ratings

Optional Equipment

options

  • Options not available
CG - ATS (General Purpose)

Cat® CG – ATS for general purpose applications

Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A
CS - ATS (Spec Grade)

Cat® CS – ATS (Spec Grade)

Rating Range:
100 - 3000 A
Transfer Type:
Open Transition (CBS), Delayed Transition (CBSD), Closed Transition (CBSCT), with Bypass Isolation
Switch Type:
Contactor
Product nodes:
UL: Open transition 100-3000A, Delayed transition 100-3000A, Closed transition 1000-3000A