3516E Generator Set
- new - Products
- 3516E Generator Set
At a glance data:
Maximum Rating:
3500 kVA
Minimum Rating:
3000 kVA
Emissions/Fuel Strategy:
Tier 2 Equivalent - 1800 rpm
Voltage:
380 to 11000 volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Maximum Rating:
3500 kVA
Minimum Rating:
3000 kVA
Emissions/Fuel Strategy:
Tier 2 Equivalent - 1800 rpm
Voltage:
380 to 11000 volts
Frequency:
50 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Mission Critical
Engine Specifications
Engine Model:
3516E, V-16, 4-Stroke Water-Cooled Diesel
Bore:
6.69in
Stroke:
8.46in
Displacement:
4765in³
Compression Ratio:
14.7:1
Aspiration:
ATAAC
Fuel System:
Electronic Unit Injection
Governor Type:
Adem™5
Generator Set Dimensions
Length - Minimum:
335.1in
Length - Maximum:
335.1in
Width - Minimum:
104in
Width - Maximum:
104in
Height - Minimum:
132.6in
Height - Maximum:
131.6in
Dry Weight - Genset (minimum):
47,620lb
Dry Weight - Genset (maximum):
50,706lb
Standard Equipment
air inlet system
- Air cleaner; single element canister type
control system
- Text alarm/event descriptions
- Emergency stop pushbutton
- IVR includes reactive droop capability
- KVAR / PF modes
- EMCP 4.2B
- 3 Phase voltage sensing
- Generator mounted - rear facing
- Generator set packages include:
- 24 Volt DC operation
- Caterpillar's voltage regulator
- RFI suppression
- Environmental sealed front face
- Limiter and exciter diode monitor
- Min / max exciter
- Controls:
- Speed adjust
- Alarm acknowledge
- Auto/start/stop control
- Engine cycle crank
- Engine cool
- Customizable screens
- PLC functionality
- Lamp test
- Load histogram feature
- Accessory module data link
- Reverse power (kW) (32)
- 6 Customer programmable digital inputs
- 3 Phase
- +/- 2% accuracy
- High coolant temperature
- 0 True RMS AC metering
- Programmable protective relaying functions:
- Reverse reactive power (kVAr) (32RV)
- Communications:
- Generator phase sequence
- Over/under voltage (27/59)
- Overcurrent (50/51)
- RPM
- Number of I/O varies on options selected
- Overspeed
- Serial annunciator module data link
- Low coolant temperature
- 4 Programmable relay outputs (Form A)
- 1 Programmable relay outputs (Form C)
- 3 Analog inputs
- Over/under frequency (81 o/u)
- Digital indication for:
- Low coolant level
- Failure to start (overcrank)
- Cat connect
- 1 Programmable digital outputs
- DC volts
- Operating hours
- Coolant temperature
- Oil pressure (psi, kPa or bar)
- Amps (per phase & average)
- Power factor (per phase & average)
- Frequency (Hz)
- Volts (L-L & L-N)
- kW (per phase, average & percent)
- kVA (per phase, average & percent)
- kVAr (per phase, average & percent)
- Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -
- Low oil pressure
- kW-hr (total)
- kVAr-hr (total)
cooling system
- ATAAC - 3516E package radiators shipped installed
- Certified standard PGS provided
exhaust system
- Flanged faced outlet(s)
- Dry exhaust manifold
fuel system
- Secondary fuel filters
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
general
- Right hand servicing
- Caterpillar yellow with high gloss black rails and radiator
- SAE standard rotation
- Flywheel and flywheel housing - SAE No. 00
generator and attachments
- NEMA standard hole pattern
- Medium voltage:
- Anti-condensation space heater
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
- Winding temperature detectors
- High voltage:
- Busbar connections, right side extension box, bottom cable entry
- Form wound
- Low voltage: Random wound - Internal excitation (IE) - Winding temperature detectors - NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
- 6 Lead
- Permanent magnet excitation (PMG)
- 3 Phase brushless, Salient pole
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
governing system
- ADEM A5
literature
- Parts book
- Operation & Maintenance Manual
lubrication system
- Integral lube oil cool
- Oil filter, filler and dipstick
- Oil drain lines and valve
- Gear type lube oil pump
- Lubricating oil
- Fumes disposal
mounting system
- Rails - Engine/generator/radiator mounting
- Anti-vibration mounts (shipped loose)
- Rubber anti-vibration mounts - shipped loose
starting system
- 24 Volt electric starting motor
- Battery disconnect switch
- Battery and battery rack w/cables
- 45 Amp Charging alternator
Optional Equipment
control system
- EMCP 4.4
air inlet system
- Single element filter
- Dual element air cleaner
cooling system
- Standard ambient radiators
- Water level switch gauges
- Optional installed ATAAC radiators
- Optional installed radiators
- Coolant
- Standard ambient ATAAC radiators
crankcase system
- Ventilation system
- No explosion relief valves
- Explosion relief valves
exhaust system
- Y Adapters
fuel system
- Fuel priming pumps (Tier 4) - Manual or electric
- Primary fuel filter
general
- Special paint (Colors other than Caterpillar yellow or high performance paints)
- US aid emblem
generators and attachments
- Space heater
- Differential current transformers (DCT) 8.7 kV and 15 kV classes
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
- Alternator air cleaner
- Thermostat for space heater
- Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames
- Generator conversion
instrumentation
- Pyrometer and thermocouples
lubrication system
- Oil level regulator
- Prelube pumps
- Lube oil in standard sump
mounting system
- Puck style low efficiency isolators
- Spring type vibration isolators
- IBC vibration isolators
power connections
- Neutral ground connections
- Center post busbars
- Right side power connections
special tests / reports
- Generator set fuel consumption test
- PGS Test report @ 1.0 power factor
- Standard engine test charge
- Canadian Standards Association certification
- Generator test report
- IBC Certification
- OSHPD Certification
- Fuel consumption test
- Torsional vibration analysis reports
- PGS Test report @ 0.8 power factor
starting and charging
- Starter cover
- Air pressure regulator
- 10, 20, 35 and 50 Amp Battery chargers
- 24 Volt battery set - Dry
- Jacket water heaters
- Air starting motors
- Electric starting motors
- Engine barring device
extended service coverage
- Platinum, Gold and Silver coverage
Cat Switchgear
Maximum Rating:
3500 kVA
Minimum Rating:
3000 kVA
Emissions/Fuel Strategy:
Tier 2 Equivalent - 1800 rpm
Voltage:
380 to 11000 volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Maximum Rating:
3500 kVA
Minimum Rating:
3000 kVA
Emissions/Fuel Strategy:
Tier 2 Equivalent - 1800 rpm
Voltage:
380 to 11000 volts
C9 Generator Set
Maximum Rating:
3500 kVA
Minimum Rating:
3000 kVA
Emissions/Fuel Strategy:
Tier 2 Equivalent - 1800 rpm
Voltage:
380 to 11000 volts
DE165E0 (50 Hz) Generator Set
Maximum Rating:
3500 kVA
Minimum Rating:
3000 kVA
Emissions/Fuel Strategy:
Tier 2 Equivalent - 1800 rpm
Voltage:
380 to 11000 volts