At a glance data:
Prime Power Rating:
2275/2000 kVA
Continuous Rating:
2000/1750 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 Volts
Overview
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Generator Set Specifications
Prime Power Rating:
2275/2000 kVA
Continuous Rating:
2000/1750 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 Volts
Frequency:
50 Hz
Speed:
1500 rpm
Duty Cycle:
Prime, Continuous
Maximum Rating:
2275 kVA
Minimum Rating:
1750 kVA
Engine Specifications
Engine Model:
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore:
6.69in
Stroke:
7.48in
Stroke - HD:
8.46in
Displacement:
4210.64in
Displacement - HD:
4764.73in³
Compression Ratio:
14.0:1 Std 15.5:1 HD
Aspiration:
TA
Fuel System:
Electronic unit injection
Governor Type:
Adem™4
Generator Set Dimensions
Length - Minimum:
278.2in
Length - Maximum:
292in
Width - Maximum:
90in
Height - Maximum:
92.9in
Dry Weight - Genset (minimum):
33300lb
Dry Weight - Genset (maximum):
36280lb
Standard Equipment
air inlet system
- Air cleaner, single element canister type
control system
- Low oil pressure
- Over/under frequency (81 o/u)
- Alarm acknowledge
- Oil pressure (psi, kPa or bar)
- Reverse reactive power (kVAr) (32RV)
- 3 Analog inputs
- Programmable protective relaying functions:
- 4 Programmable relay outputs (Form A)
- Overspeed
- Reverse power (kW) (32)
- Customer data link (Modbus RTU)
- Text alarm/event descriptions
- Low coolant temperature
- Number of I/O varies on options selected
- Emergency stop
- Operating hours
- Limiter and exciter diode monitor
- Environmental sealed front face
- kW (per phase, average & percent)
- Digital indication for:
- Auto/start/stop control
- Cat connect
- Low coolant level
- Controls:
- Serial annunciator module data link
- Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
- RPM
- Volts (L-L & L-N), frequency (Hz)
- Coolant temperature
- 1 Programmable digital outputs
- Speed adjust
- Engine cycle crank
- Over/under voltage (27/59)
- kW-hr (total)
- 6 Customer programmable digital inputs
- Generator phase sequence
- 1 Programmable relay outputs (Form C)
- PLC functionality
- kVAr-hr (total)
- DC volts
- Engine cool-down timer
- 24 Volt DC operation
- Generator mounted - rear facing
- High coolant temperature
- Amps (per phase & average)
- Load histogram feature
- Emergency stop pushbutton
- Warning/shutdown with common LED indication of shutdowns for:
- kVAr (per phase, average & percent)
- Customizable screens
- True RMS AC metering, 3-phase, +/-2% accuracy
- Overcurrent (50/51)
- Communications:
- kVA (per phase, average & percent)
- Power factor (per phase & average)
- Failure to start (overcrank)
- Accessory module data link
- Lamp test
- Generator set packages include Caterpillars voltage regulator
exhaust
- Exhaust flange outlet
fuel
- Primary fuel filter with integral water separator
generator
- IP23 Protection
power termination
- Busbar
control panel
- Cat ECS Genset controller
cooling system
- Package mounted radiator
exhaust system
- Dry exhaust manifold
- Flanged faced outlet(s)
fuel system
- Fuel priming pump
- Fuel cooler; not included with packages without radiator
- Flexible fuel lines - shipped loose
- Secondary fuel filters
general
- SAE standard rotation
- Paint - Caterpillar yellow except rails and radiators gloss black
- RH service
- Flywheel and Flywheel housing-SAE No. 00
generators and attachments
- Matched to the performance and output characteristics of Cat engines
- Random wound
- Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
- Permanent magnet excitation (PMG)
- LV
- HV:
- MV:
- 6 Lead
- Winding temperature detectors
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
- Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
- 3 Phase brushless, Salient pole
- Anti-condensation space heater
- NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
- Form wound
governing system
- ADEM A3
lube system
- Gear type lube oil pump
- Oil filter, filler and dipstick
- Oil drain lines and valve
- Integral lube Oil cooler
- Lubricating oil
- Fumes disposal
mounting system
- Rails - Engine/generator/radiator mounting
- Rubber anti-vibration mounts - shipped loose
- Anti-vibration mounts (shipped loose)
starting system
- 45 Amp Charging alternator
- 24 Volt electric starting motor
- Battery disconnect switch
- Battery and battery rack w/cables
Optional Equipment
exhaust
- Exhaust mufflers
air inlet system
- Dual element air cleaner
- Standard ambient radiators
- Single element filter
- Standard ambient ATAAC radiators
- Optional radiator arrangements
generator
- Permanent magnet excitation (PMG)
- Oversize and premium generators
- Internal excitation (IE)
- Anti-condensation heater
control panels
- Load share module
- Empty upper box
- Generator main terminal box
- Annunciator - remote
- EMCP 4.4
- Digital I/O module
- Cable Shroud
- Remote monitoring software
- Vandal proof panel cover
- Side extension box
- Generator temperature monitoring & protection
- Annunciator - local
cooling system
- Water level switch gauges
- Coolant
mounting
- IBC isolators
- Spring type vibration isolators
crankcase systems
- No explosion relief valves
- Explosion relief valves
- Crankcase ventilation systems
- Crankcase protection groups:
exhaust system
- Tier 4 dosing cabinet
- Y Adapters
- Flanges
- Flange and exhaust expanders
- Elbows>
- Mufflers
- Tier 4 lean emissions moDual
- Clean emission parts
- Flexible fittings
- Tier 4 clean emission MOD kits
- Exhaust offset
starting/charging
- Charging alternator
- Battery chargers
- Oversize batteries
- Heavy duty starting system
- Jacket water heater
- Air starting motor with control and silencer
extended service coverage
- Platinum, Silver and Gold coverage
general
- The following options are based on regional and product configuration:
- UL 2200 package
- EEC Declaration of Conformity
- CSA Certification
- Enclosures: Sound attenuated, weather protective
- EU Certificate of Conformance (CE)
- Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
- Integral & sub-base UL listed dual wall fuel tanks
- Automatic transfer switches (ATS)
- Integral & sub-base fuel tanks
fuel system
- Gas fuel filter
- Primary fuel filter
- Fuel priming pumps (Tier 4)
generators and attachments
- 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm ,FW, PM, No. of leads = 6, Pitch = .6667
- Hi voltage optional attachments
- Differential current transformers
- 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, PM, No. of leads = 6, Pitch = .6667
- Generators high voltage
- Space heater kit
- Generator conversions
- 1600 Frame - 380, 400, 415 Volts, 3 Phase 1500 rpm, RW, IE, No. of leads = 6, Pitch = .6667
- 2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
- 3000 Frame - 10000, 10500, 11000 Volts, 3 Phase 1500 rpm, FW, PM, No. of leads = 6, Pitch = .6667
- 1800 Frame
- Alternator air cleaner
instrumentation
- Pyrometer and termocouples
lube system
- Prelube pump groups
- Oil level regulator
- Lube oil in standard sump
mounting system
- IBC vibration isolators
- Puck style low efficiency isolators
- Spring type vibration isolators
power connections
- Cable entry - right side
- Cable entry - rear
- Grounding groups
- left side power connections
- Neutral ground connections
- Center post busbars
- Right side power connections
- Cable entry - left side
- Rear power connections
power termination
- Circuit breakers - LV packages
- Circuit breakers, UL listed
- 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
- Circuit breakers, IEC compliant
- 2000, 2500, 3200 Amp, 4 Pole, IEC rated Circuit breakers
- 1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
special tests / reports
- Standard engine test
- Torsional vibration analysis
- Fuel consumption test
- PGS Test report @ 1.0 power factor
- OSPD Certification
- PGS Test report @ 0.8 power factor
- Generator set report
starting / charging
- Engine barring device
- Electric starting motors
- Jacket water heaters
- Starter cover
- Batteries, racks and cables
- Air pressure regulator
- 10, 20, 35 Amp Battery chargers
- 50 Amp NFPA battery charger
- Air starting motors
Cat Switchgear
Prime Power Rating:
2275/2000 kVA
Continuous Rating:
2000/1750 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 Volts
Similar Products
DE75AE0 (50 Hz) Generator Set
Prime Power Rating:
2275/2000 kVA
Continuous Rating:
2000/1750 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 Volts
C9 Generator Set
Prime Power Rating:
2275/2000 kVA
Continuous Rating:
2000/1750 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 Volts
DE165E0 (50 Hz) Generator Set
Prime Power Rating:
2275/2000 kVA
Continuous Rating:
2000/1750 kVA
Emissions/Fuel Strategy:
Low Fuel Consumption
Voltage:
380 to 11000 Volts