Skip to content

3512C Generator Set

At a glance data:

Standby Rating:
1500 ekW
Prime Power Rating:
1360 ekW
Emissions/Fuel Strategy:
U.S. EPA Certified
Voltage:
380 to 13800 Volts

Overview

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

Generator Set Specifications

Standby Rating:
1500 ekW
Prime Power Rating:
1360 ekW
Emissions/Fuel Strategy:
U.S. EPA Certified
Voltage:
380 to 13800 Volts
Frequency:
60 Hz
Speed:
1800 rpm
Duty Cycle:
Standby, Mission Critical, Prime, Continuous
Maximum Rating:
1500 ekW
Minimum Rating:
1230 ekW

Engine Specifications

Engine Model:
3512C ATAAC, V-12, 4-Stroke Water-Cooled Diesel
Bore:
6.69in
Stroke:
7.48in
Displacement:
3161.03in³
Compression Ratio:
14.7:1
Aspiration:
TA
Fuel System:
Electronic unit injection
Governor Type:
ADEM™ A3

Generator Set Dimensions

Length - Maximum:
248.6in
Width - Maximum:
89.8in
Height - Maximum:
110in
Dry Weight - Genset (maximum):
30790lb

Standard Equipment

air inlet system

  • Air cleaner; single element canister type with service indicator

air inlet

  • Air cleaner

cooling

  • Package mounted radiator

exhaust

  • Exhaust flange outlet

fuel

  • Secondary fuel filters
  • Primary fuel filter with integral water separator
  • Fuel priming pump

generator

  • Matched to the performance and output characteristics of Cat engines
  • IP23 Protection

power termination

  • Busbar

control panel

  • Cat ECS Genset controller

control system

  • Alarm acknowledge
  • Over/under frequency (81 o/u)
  • Reverse power (kW) (32)
  • Coolant temperature
  • kVAr (per phase, average & percent)
  • Overcurrent (50 / 51)
  • High coolant temperature
  • Environmental sealed front face
  • Reverse reactive power (kVAr) (32RV)
  • kVA (per phase, average & percent)
  • Volts (L-L & L-N)
  • Generator set packages include Caterpillar's voltage regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
  • kW-hr (total)
  • kW (per phase, average & percent)
  • Low oil pressure
  • Cat ECS 100
  • Digital indication for:
  • Engine cool-down timer
  • Generator mounted - rear facing
  • DC volts
  • 1 programmable relay outputs (Form C)
  • Overspeed
  • kVAr-hr (total)
  • 1 programmable digital outputs
  • Communications
  • Power factor (per phase & average)
  • Oil pressure (psi, kPa or bar)
  • True RMS AC metering, 3-phase, +/-2% accuracy
  • Cat connect
  • Customizable screens
  • Low coolant temperature
  • Over/under voltage (27 / 59)
  • 4 programmable relay outputs (Form A)
  • Accessory module data link
  • Warning/shutdown with common LED indication of shutdowns for:
  • Failure to start (overcrank)
  • Amps (per phase & average)
  • Auto/start/stop control
  • Controls:
  • Engine cycle crank
  • Customer data link (Modbus RTU)
  • Programmable protective relaying functions:
  • Text alarm/event descriptions
  • Emergency stop
  • Speed adjust
  • Number of I/O varies on options selected
  • Lamp test
  • RPM
  • 24 Volt DC operation
  • Emergency stop pushbutton
  • Low coolant level
  • Frequency (Hz)
  • Generator phase sequence
  • Load histogram feature
  • PLC functionality

cooling system

  • Coolant level sensors (Not included with packages without radiator)
  • SCAC
  • Radiator fan and fan drive
  • Coolant drain line with valve
  • Fan and belt guards
  • Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS

exhaust system

  • Flanged faced outlet(s)
  • Dry exhaust manifold

fuel system

  • Fuel cooler; not included with packages without radiator
  • Secondary fuel filters
  • Flexible fuel lines - shipped loose
  • Fuel priming pump

generators and attachments

  • Medium voltage:
  • Internal excitation (IE)
  • High voltage
  • Permanent magnet excitation (PMG)
  • Winding temperature detectors
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
  • Busbar connections, right side extension box, bottom cable entry
  • Busbar connections, top center mounted, top cable entry
  • Low voltage:
  • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
  • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime / 150C standby)
  • NEMA standard hole pattern
  • 3 phase brushless, Salient pole
  • NEMA standard hole pattern
  • 6 Leads
  • Random wound
  • NEMA standard hole pattern
  • Form wound

governing system

  • ADEM III

literature

  • Parts book

lube system

  • Gear type lube oil pump
  • Oil filter, filler and dipstick
  • Fumes disposal
  • Lubricating oil
  • Oil drain lines and valve
  • Integral lube Oil cooler

mounting system

  • Rubber anti-vibration mounts - shipped loose

starting / charging system

  • 45 Amp Charging alternator
  • Battery and battery rack w/cables
  • Battery disconnect switch
  • 24 Volt electric starting motor

general

  • Flywheel and Flywheel housing-SAE No. 00
  • SAE standard rotation
  • Right hand servicing
  • Paint - Caterpillar yellow with high gloss black rails & radiator

Optional Equipment

control panels

  • EMCP 4.4

exhaust

  • Exhaust mufflers

air inlet system

  • Heavy duty air cleaner
  • Single element filter

generator

  • Permanent magnet excitation (PMG)
  • Oversize and premium generators
  • Internal excitation (IE)
  • Anti-condensation heater

cooling system

  • Coolant
  • Standard installed ATAAC radiators
  • Optional installed ATAAC radiators
  • Optional installed radiators
  • Water level switch gauges
  • Standard installed radiators

power termination

  • Circuit breakers, IEC compliant
  • Circuit breakers, UL listed

exhaust system

  • Flanges
  • Flange and exhaust expanders
  • Y Adapters
  • Flexible fittings
  • Elbows
  • Mufflers

fuel system

  • Primary fuel filter

general

  • US aid emblem

mounting

  • IBC isolators
  • Rubber anti-vibration mounts
  • Spring type vibration isolators

generators and attachments

  • Differential current transformers (DCT) 15 kV class
  • RW, IE, 6 Leads, Pitch 0.6667
  • Differential current transformers (DCT) 8.7 kV class
  • 1400, 1600, 2700 Frames
  • Space heater
  • Generator air cleaner
  • Generator conversion from IE to PM
  • Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm

starting/charging

  • Jacket water heater
  • Air starting motor with control and silencer
  • Battery chargers
  • Charging alternator
  • Heavy duty starting system
  • Oversize batteries

instrumentation

  • Wiring GP W/O cyl sensors
  • Pyrometer and thermocouples

lube system

  • Prelube pumps
  • Oil level regulator
  • Oil drains
  • Lubrication oil in standard sump

crankcase protection

  • No explosion relief valves
  • No crankcase explosion relief valves
  • Explosion relief valves
  • Crankcase ventilation system

mounting system

  • Puck style low efficiency isolators
  • IBC vibration isolators
  • Spring type vibration isolators

power connections

  • Cable entry - right side
  • Center post buss bar
  • Rear power connections
  • Right side power connections
  • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
  • 1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
  • Left side power connections
  • Six lead, six terminal option
  • 2000, 2500 Amp, 4 Pole, IEC rated Circuit breakers
  • Neutral ground connections
  • Grounding groups

special tests / reports

  • Standard engine test charge
  • PGS Test report @ 1.0 power factor
  • CSA Certification
  • IBC seismic Certification
  • Fuel consumption test
  • Torsional vibration analysis
  • Generator test report
  • Generator fuel consumption test
  • PGS Test report @ 0.8 power factor

starting / charging system

  • 10 Amp Battery charger
  • 24 Volt battery set - Dry
  • Engine barring device
  • 35 Amp Battery charger
  • Air starting motor
  • Air pressure regulator
  • Batteries, racks and cables:
  • Jacket water heaters
  • Electric starting motors
  • Starter cover
Cat Switchgear

Cat Switchgear

Standby Rating:
1500 ekW
Prime Power Rating:
1360 ekW
Emissions/Fuel Strategy:
U.S. EPA Certified
Voltage:
380 to 13800 Volts